6.12 Remove the Shaft Sealing
Before you remove casing cover refer to
Mounting Instructions for Shaft Sealing
.
1.
Unfasten hexagonal nut (902.32) (not available on all pump sizes) and take casing cover (161) out
of bearing bracket (344).
6.13 Removal of Bearing
1.
Remove coupling with a coupling puller (
Figure 18: Coupling puller on page 38
), remove coupling
key (940.52).
Figure 18: Coupling puller
2.
Remove the flinger (507) axially by using 2 screw drivers.
Figure 19: Flinger removal
3.
Loosen hexagon head bolt (901.41). Remove the bearing bracket lantern from bearing bracket
(330).
4.
Dismount circlip (932.51). Therefore you need a snap ring plier according to DIN 5256-C.
Bearing
bracket
required snap ring pli-
er
length i (min.) of snap
ring plier
24
size 94/C 40
200mm
32, 42
size 94/C 85
250mm
48
Größe 94/C 85
300mm
5.
Remove shaft (210) including anti-friction bearing (320.51 and 320.52) and bearing nut (923.51)
from the bearing bracket (330).
6.
Remove the bearing nut (923.51). The bearing nut is right hand threaded and self locking. It can be
reused 5 times if it is handled appropriately.
6.12 Remove the Shaft Sealing
38
Model ICP, ICPI, ICPH, ICPIH Installation, Operation and Maintenance Instruction
Содержание Goulds Pumps ICP
Страница 1: ...Installation Operation and Maintenance Instruction Model ICP ICPI ICPH ICPIH ...
Страница 2: ......