WARNING
NEVER use heat to disassemble pump due to risk of explosion from tapped
liquid.
WARNING
NEVER operate pump without coupling guard correctly installed.
WARNING
NEVER run pump below recommended minimum flow when dry, or without
prime.
WARNING
ALWAYS lock out power to the driver before performing pump maintenance.
WARNING
NEVER operate pump without safety devices installed.
WARNING
NEVER operate pump with discharge valve closed.
WARNING
NEVER operate pump with suction valve closed.
WARNING
DO NOT change service application without approval of an authorized ITT
Goulds Pumps representative.
WARNING
Safety Apparel:
•
Insulated work gloves when handling hot bearings or using bearing
heater
•
Heavy work gloves when handling parts with sharp edges, especially
impellers
•
Safety glasses (with side shields) for eye protection
•
Steel-toed shoes for foot protection when handling parts, heavy tools,
etc.
•
Other personal protective equipment to protect against hazardous/toxic
fluids
WARNING
Receiving:
Assembled pumping units and their components are heavy. Failure to properly
lift and support equipment can result in serious physical injury and/or equip-
ment damage. Lift equipment only at specifically identified lifting points or as
instructed in the current IOM. Current manuals are available at www.gould-
spumps.com/literature_ioms.html or from your local ITT Goulds Pumps sales
representative. Note: Lifting devices (eyebolts, slings, spreaders, etc.) must
be rated, selected, and used for the entire load being lifted.
WARNING
Alignment:
Shaft alignment procedures must be followed to prevent catastrophic failure of
drive components or unintended contact of rotating parts. Follow coupling
manufacturer's coupling installation and operation procedures.
WARNING
Before beginning any alignment procedure, make sure driver power is locked
out. Failure to lock out driver power will result in serious physical injury.
CAUTION
Piping:
Never draw piping into place by forcing at the flanged connections of the
pump. This may impose dangerous strains on the unit and cause misalign-
ment between pump and driver. Pipe strain will adversely effect the operation
of the pump resulting in physical injury and damage to the equipment.
WARNING
Flanged Connections:
Use only fasteners of the proper size and material.
WARNING
Replace all corroded fasteners.
WARNING
Ensure all fasteners are properly tightened and there are no missing fasten-
ers.
WARNING
Startup and Operation:
1.4 General precautions
4
Model HS Installation, Operation, and Maintenance Manual
Содержание Goulds Pumps HS
Страница 1: ...Installation Operation and Maintenance Manual Model HS ...
Страница 2: ......