7 Troubleshooting
7.1 Operation troubleshooting
Symptom
Cause
Remedy
The pump is not deliver-
ing liquid.
The pump is not primed.
Re-prime the pump and check that the pump
and suction line are full of liquid.
The suction line is clogged.
Remove the obstructions.
The impeller is clogged.
Back-flush the pump in order to clean the im-
peller.
The shaft is rotating in the wrong direction. Change the rotation. The rotation must match
the arrow on the bearing housing or pump
casing.
The foot valve or suction pipe opening is
not submerged enough.
Consult an ITT representative for the proper
submersion depth. Use a baffle in order to
eliminate vortices.
The suction lift is too high.
Shorten the suction pipe.
The pump is not produc-
ing the rated flow or
head.
The gasket or O-ring has an air leak.
Replace the gasket or O-ring.
The stuffing box has an air leak.
Replace or readjust the mechanical seal.
The impeller is partly clogged.
Back-flush the pump in order to clean the im-
peller.
The clearance between the impeller and
the pump casing is excessive.
Adjust the impeller clearance.
The suction head is not sufficient.
Make sure that the suction-line shutoff valve
is fully open and that the line is unobstructed.
The impeller is worn or broken.
Inspect and replace the impeller if necessary.
The pump starts and
then stops pumping.
The pump is not primed.
Re-prime the pump and check that the pump
and suction line are full of liquid.
The suction line has air or vapor pockets. Rearrange the piping in order to eliminate air
pockets.
The suction line has an air leak.
Repair the leak.
The bearings are running
hot.
The pump and driver are not aligned prop-
erly.
Realign the pump and driver.
There is not sufficient lubrication.
Check the lubricant for suitability and level.
The lubrication was not cooled properly.
Check the cooling system.
The pump is noisy or vi-
brates.
The pump and driver are not aligned prop-
erly.
Realign the pump and driver.
The impeller is partly clogged.
Back-flush the pump in order to clean the im-
peller.
The impeller or shaft is broken or bent.
Replace the impeller or shaft as necessary.
The foundation is not rigid.
Tighten the hold-down bolts of the pump and
motor. Make sure the baseplate is properly
grouted without voids or air pockets.
The bearings are worn.
Replace the bearings.
The suction or discharge piping is not
anchored or properly supported.
Anchor the suction or discharge piping as
necessary according to recommendations in
the Hydraulic Institute Standards Manual.
The pump is cavitating.
Locate and correct the system problem.
The mechanical seal is
leaking excessively.
The packing gland is not adjusted proper-
ly.
Tighten the gland nuts.
7 Troubleshooting
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual