WARNUNG:
or if the environment is classified as potentially explosive.
5.3 Lubrication
Pump bearings are normally grease lubricated and are lubricated at the factory. Regrease at approxi-
mately 3-6 month intervals, until grease comes out the oil caps which
serve as grease relief fittings. Use a sodium or lithium base grease, NLGI #2 consistency. Follow mo-
tor and coupling manufacturer's lubrication instructions.
5.4 Maintenance of Bearings
Do not insulate bearing housings as this can result in excess heat generation, sparks,
and premature failure.
Service temperature in an ATEX classified environment is limited to the area classificati-
on specified on the ATEX tag affixed to the pump, refer to
Tabellennummer 1: Definition der Tempe-
.
Bei ATEX-Anwendungen wird der Austausch aller Lager nach 17.500 Betriebsstunden
empfohlen.
5.5 Fettgeschmierte Lager
Fettgeschmierte Lager sind werksseitig vorgeschmiert. Fetten Sie die Lager alle 2000 Betriebsstun-
den oder 3 Monate nach, je nachdem, was zuerst eintritt.
Verfahren zur Nachfettung
HINWEIS:
Bei der Nachfettung besteht die Gefahr, dass Verunreinigungen in das Lagergehäuse ge-
langen. Der Fettbehälter, die Abschmiervorrichtung und die Nippel müssen sauber sein.
1.
Wischen Sie Schmutz von beiden Schmiernippeln ab.
Abbildungsnummer 12:
5.3 Lubrication
32