2.
Between 220ºF and 250ºF.
3.
Between 250ºF and 350ºF, in addition to gland quenching.
The inlet piping must be at the bottom and the outlet at the top as shown in the sectional assembly , refer
to
7.4 Sectional views, parts list and interchangeability tables on page 29
side of the frame and the outlet on the other side. The remaining holes must be plugged. The cooling
liquid must be supplied from an outside source and a shut-off valve should be installed in the supply line
to regulate the flow of the cooling liquid.
3.7 Connection of drain piping
Connect the ¾" pipe tap openings (from the drip pockets directly below the stuffing box) to drain. On
pumps equipped with a drip basin (247) connect to the tapped opening on the end of the drip basin (¼"
pipe tap on Group S and 3/8" on Group M and L) and out through the frame to drain.
3.7 Connection of drain piping
20
Model 3755 Installation, Operation, and Maintenance Manual