Figure 36:
3.
Impeller wearing rings:
if the unit has impeller wearing rings and it is necessary to replace the
rings:
1.
Remove old rings by removing the three set screws and pulling ring off hub.
2.
Clean hub and press on new ring.
3.
Drill and tap three holes 120 degrees apart with an "l" drill and a 5/16"-18NC cap in each
ring. Use 5/15" x 5/15" cup point safety set screws. Tighten screws and lightly "upset"
threads. See
Table 3: Impeller and Wearing Ring Clearance on page 41
.
4.
Replacement impeller rings are supplied .020-.030" oversize and must turned to size after
mounting on impeller. See
Table 3: Impeller and Wearing Ring Clearance on page 41
dimensions.
Table 3: Impeller and Wearing Ring Clearance
Material
Dimen-
sion
Pump Size
8x10-22 12x14-1
8
14x16-1
8
16x18-1
8
10x12-2
2
14x16-2
2
16x18-2
2H
18x20-2
2
Dimensions below in inches
Iron and
Bronze
A
8.989
8.987
10.753
10.751
12.236
12.233
13.986
19.983
10.238
10.236
12.986
12.983
14.234
14.231
15.359
15.356
B
.020
.024
.022
.026
.023
.029
.023
.029
.022
.026
.023
.029
.023
.029
.023
.029
C
9.854
9.852
12.477
12.474
13.102
13.099
14.852
14.849
11.102
11.100
14.477
14.474
15.602
15.599
16.477
16.474
6.5 Inspection and Overhaul
Model 3415 Installation, Operation, and Maintenance Manual
41