1
2
3
1.
Frame-to-adapter hex screw (370B)
2.
Close-coupled adapter (503)
3.
Frame-to-adapter gasket (360W)
Figure 33: Close-coupled pump assembly
6.5.3 Reassemble the liquid end
1.
Insert the bearing cartridge (849) into the backplate (444).
1
2
3
1.
Backplate (444)
2.
Cartridge-to-backplate hex screw (791E)
3.
Bearing cartridge assembly (849)
2.
Rotate the bearing cartridge until all three holes line up and secure with hex screws (791E).
See
6.5.5 Bolt torque values on page 75
3.
For M-group pumps, if the driven carrier pin (445A) in the driven magnet assembly (740A) must be
replaced, then drive in the carrier pin carefully until it protrudes approximately 3.05 mm | 0.12 in.
towards the impeller.
The S-group has a drive key, which is automatically placed into position during installation when in-
stalled.
6.5 Reassembly
Model 3296 EZMAG Installation, Operation, and Maintenance Manual
71
Содержание GOULDS PUMPS 3296 EZMAG
Страница 1: ...Installation Operation and Maintenance Manual Model 3296 EZMAG ...
Страница 2: ......