4.
Pry the Shearpeller
TM
off of the shaft using two bars opposite of each other, placed between the
cover and the Shearpeller
TM
shroud.
You can also use an impeller puller.
101
1
1.
Impeller puller
6.4.9 Remove the stuffing box cover
WARNING:
Stuffing box covers are heavy. Use proper support to avoid personal injury.
1.
Remove the packing gland halves (107), packing (106), lantern ring (105), and throttle bushing
(125).
2.
Thread a 10 mm eye bolt into the tapped hole provided in the cover (184) and sling to a hoist.
3.
Remove the hex head bolts:
If your pump group is... Then...
S, M, L, and XL
Remove the eight hex head bolts (370B) from the cover (184).
XL1, XL2-S, and XL2
Remove the two hex head bolts (370H) from the frame adapter (108).
4.
Remove the cover:
If your pump group
is...
Then...
S, M, L, and XL
Gently tap the cover from the frame using a soft-blow hammer on the dry side of the
cover.
XL1, XL2-S, and XL2 Evenly tighten the two jacking bolts (418) until the cover is free enough to remove from
the frame adapter. If required, gently tap the cover from the frame adapter using a soft-
blow hammer on the dry side of the cover.
This example shows S, M, L, and XL:
6.4 Disassembly
86
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...