1. Shaft
2. Sleeve
3. Scribe
4. Stuffing box
Figure 68: Shaft sleeve
b) Unbolt and remove the stuffing box cover. Remove sleeve. Lightly lubricate the rotary portion of
the seal and slide onto the sleeve.
c)
Compress the rotary to the correct "working length". Refer to the seal manufacturer's drawing
for correct dimensions. Tighten set screws.
6.9 Stuffing Box
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
The standard stuffing box cover has four pipe taps for sealing or flushing liquid to the packing or mechan-
ical seal. Two are used for in and out connections to the throat of the stuffing box for paper stock serv-
ices with the lantern ring positioned next to the stuffing box throat bushing. Two are alternately used for
evaporator or chemical services as in and out connections. The image below shows a stuffing box and
location of holes, and the holes used for evaporator service and paper stock service.
6.9 Stuffing Box
68
3175 Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3175