6
Operation
DANGER!
Mortal danger due to explosion!
Observe the additional explosion protection instructions!
For pumps as part of a pump system
Pump system operating
instructions.
NOTICE!
Irreparable damage to the pump system due to throttling on the
outlet side!
–
Severe loading of the pump due to liquid sludge with throttling
on the outlet side.
–
Never operate the pump against a closed or partially closed
valve in the outlet line.
–
Never throttle the outlet side.
6.1 Performing initial commissioning
WARNING!
Risk of injury due to unprofessional work!
–
Only allow work to be carried out by technical specialists who
have the required knowledge and practical experience to do so:
–
Installation, initial commissioning, repairs, maintenance
–
Work on the electrical and electronic systems.
–
Make personal safety equipment available.
–
Observe statutory or other safety and accident prevention regu-
lations.
6.1.1 Determining the pump type
Determining the pump type (
pump data sheet).
The pump type refers to e.g. the type of bearing lubrication, lip seal
type, auxiliary operating systems.
Operation
46
Type SLH-4U
0
3
/20
20
JP Rev. 1