background image

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C 

08172 Sant Cugat del Vallés · Barcelona (Spain)  

Phone: +34935839543  ·  [email protected]  ·   www.ek.plus

 

 

EKSEL compact

 USER MANUAL

 

 

Allows navigating to the left in the menus.  

Increasing values where required. 

Menu Overview: 

Pressing any key will access the main menu:   

EKSEL 

COMPACT> 

Note: The arrows to the right or left indicate that there are menu options in that direction. The main 
menu options are: 

COMPACT> <FILTER MENU> <POWER SUPPLY MENU> <MISCELLANEOUS MENU 

Using 

◀▶

 to scroll through the first menu line, pressing ENTER for accessing that submenu. 

Equipment Configuration: 

COMPACT> 

FW version of the system. 

Press ENTER. [V2.1] 

<FILTERS MENU> 

Filter configuration. 

Press ENTER to enter, 

◀▶

 to move between options and ENTER 

to enter the option. 

AUTOSEARCH>  <ADD  FILTER>  <EDIT  FILTER><CANCEL  FILTER> 
<CANCEL ALL> <D.A.B.> <BACK 

<POWER MENU> 

Configuration of input voltages and output power. 

Press ENTER to enter, 

◀▶

 to move between options and ENTER 

to enter the option. 

POWER  SUPPLY.  ENT.  1>  <POWER  SUPPLY  ENT.  2>  <POWER 
SUPPLY ENT. 3> <FM GAIN> <OUTPUT LEVEL> <SLOPE> <BACK 

<MISCELLANEOUS MENU 

Miscellaneous configuration. 

Press ENTER to enter, 

◀▶

 to move between options and ENTER 

to enter the option. 

LANGUAGE> <DEFAULT VAL. > <BACK 

 

Содержание 071015

Страница 1: ...S Partner O B S S L Av Cerdanyola 79 81 Local C 08172 Sant Cugat del Vall s Barcelona Spain Phone 34935839543 info ek plus www ek plus USER MANUAL EKSEL compact 071015 PROGRAMMABLE DIGITAL AMPLIFIER V...

Страница 2: ...KSEL compact USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 Descripction 3 Main Features 3 Packaging Contents 3 CONNECTIONS AND INTERFACES 4 INSTALLATION RECOMMENDATIONS 4 EKSEL compact CONFIGURATION 4...

Страница 3: ...the requirements for header equipment stipulated by the Regulatory Regulations on Common Telecommunications Infrastructures ICT2 on common infrastructure in buildings for access to telecommunications...

Страница 4: ...mum recommended operating temperature 2 Leave a space between 15 cm and 20 cm free of obstacles around the equipment which ensures compliance with Point no 1 3 Connect a suitable earth cable to the eq...

Страница 5: ...oll through the first menu line pressing ENTER for accessing that submenu Equipment Configuration COMPACT FW version of the system Press ENTER V2 1 FILTERS MENU Filter configuration Press ENTER to ent...

Страница 6: ...the Autosearch channel start 5 6 7 12 21 22 using When ENTER is released the selected option is automatically selected AUTOSEARCH END CHANNEL Autosearch end channel selection Press ENTER and press an...

Страница 7: ...ion Press ENTER and press and hold down select the searched channel 5 6 7 12 21 22 using When ENTER is released the selected option is automatically selected Every time the channel number is changed i...

Страница 8: ...ally selected Every time the channel number is changed if it is valid the voltage will be displayed and if not the 0dB will be displayed INPUT CHANNEL 23 61dB EDIT FILTER OUTPUT CHANNEL Manual output...

Страница 9: ...MANUAL FILTER MENU CANCEL ALL Allows to delete all filters Press ENTER and press and hold down select NO YES using When ENTER is released the selected option is automatically selected FILTER MENU D A...

Страница 10: ...eased the selected option is automatically selected FM GAIN Allows FM gain variance between 8dB and 28dB Press ENTER and press and hold down using the gain can be increased or decreased OUTPUT LEVEL A...

Страница 11: ...ek plus www ek plus 11 EKSEL compact USER MANUAL An already existing output channel cannot be selected The same input channel can be selected ONLY if it is from a different input The equipment calcula...