background image

 2 - Using the RF Master
Antenna assembly
Warning

In order to be compliant with CE recommendation, the user is not use other radio equipments (antenna) than the ones 
provided by Itron or the optional external antenna reference no RFMASTERMAGANT.
RF Master is equipped with a BNC type connector. The antenna is mounted and locked by turning it turn clock wise.

Connection to the hand held terminal

Use a specific cable to connect the hand held terminal to the RF Master. 
The RF Master female plug is a 5 pins binder type.

   

 

Plug pin out

   

 

- 1: DTR

   

 

- 2: Rx

  

 

3: 

Tx 

 

   

 

- 4: +Vdd   

   

 

- 5: GND

The maximal cable length is 1.5 meter.

Operating the RF Master

Once all the above connections are done, run the radio reading software on the hand held terminal.
Thanks to the belt clip located on the rear side of the RF Master, it is easy to fix on a belt, on a pocket side or on the hand 
held belt.

LED understanding

Three diodes are located on the RF Master front side. They can be used to visualize the Communication status between 
the RF Master and the meter interface unit.

  

 

 

 

 

 

Red: Hand held terminal - RF Master communication

   Green: 

radio 

emission

   Yellow: 

radio 

reception

 Timing

Red light: handheld to RF Master communication.
Green light: radio communication from RF Master to meter interface unit.
Yellow light: meter interface unit answer receiving.

If no answer is received from the meter interface unit, the yellow LED will not switch on. 
The red LED then the green one will light again to indicate an other try (number of retries is defined by the reading 
software).

1

2

3

5

4

External view

RF MASTER

3 - Characteristics
Mechanical

Dimensions (mm): 
around (H) 112 x (L) 62 x (P) 38,
without antenna and without plug
Weight: 205 g.
Belt clip provided.
Protection level: IP 54.
Working temperature: -10°C to 55°C.
Storage temperature: -20°C to 70°C.

Electrical

Radio frequency: 433.82 MHz.
Modulation type: FSK.
Radio communication protocol: RADIAN.
Maximum radio power: 10 dBm.
Power supply: Vdd = +5 V +/- 10% regulated 
(power supplied by the hand held terminal serial 
communication port).
Communication protocol: Mbus through RS232 
link.

H

L

P

RF MASTER

Time