 8.  Installation of the EverBlu / RF option board

8.1 Open calculator

Open the meter case by unscrewing the side screws.

  

WARNING  :

Do not open the calculator or connect or disconnect the RF option
board with power supplied.

8.2 Check type of main power supply board

Make sure that the calculator is powered with a main supply board equipped with
the additional connector designed to enable the EverBlu / RF Option Board 
connection.

 WARNING 

:

Only main supply boards with the meters power supply connector cable as well as 
the RF board power supply plug are applicable for RF applications.

8.3 Check type of main power supply board

Plug the option board using the guidance clip on the right hand side of the calculator
pushing then the board until all option board connections are made.

Connect the RF board main power supply cable to the additional power supply plug 
of the main power supply board.

Make sure, that the power supply cable for the meter is correctly mounted and 
connected.

 WARNING 

:

Avoid ElectroStatic Discharges by NOT touching any electronic components.

Only manipulate the product by the side of the board and plug it pushing on the
metallic lid

 8.4  Labelling

Place the unstickable label with RF reference number at the free labelling area at 
the bottom front side of the calculator case.

8.5 Optional Water Meter configuration

In case of the use of Optional Water Meter outputs configure as described in 
Chapter 9.

8.6 Closing calculator

Close the calculator carefully with the side screws.
Switch on the main power supply.

B

A

side screws

side screws

RF board power 
supply plug

Meter power supply 
connector cable

Meter power supply

Guidance clip

RF board power supply plug

Label

Label area