¡ATTENTION!:

 THE OPERATIONS  INDICATED IN FIG. 5-1 CORRESPOND TO THE 

STANDARD RECEIVER. FOR SPECIAL MODELS YOU MUST CONSULT THE 
OPERATIONS ASSOCIATED WITH EACH RELAY IN THE RELAY OUTPUT SHEET 
PROVIDED WITH THE RECEIVER.  

 

¡ATTENTION!:

 CONNECTION SHOULD BE MADE SO THAT WHEN GENERAL 

SWITCHING IS TURNED OFF, THE REMOTE CONTROL RECEIVER IS ALSO TURNED 
OFF. 

 

¡ATTENTION!:

 AS A SAFETY MEASURE, IT IS IMPERATIVE TO MAKE SURE THE UNIT 

IS EARTHED WITH  THE CORRESPONDING PIN OF THE CONNECTOR.  

 

Itowa will not be responsible for an inappropriate installation.  

 

5.3. START-UP  

Once the receiver is installed and connected, when the general switch of the machine is turned on, the 
LED located on the front of the receiver set will light up, to verify its correct operation 

The following steps will be done with the transmitter associated with the receiver: 

  Insert  a charged  battery into the  transmitter set,  release  the STOP  BUTTON  and  press  the  START 

1)

button. 

  The  remote  control  will  start  to  work  activating  the  stop  and  start  relays  of  the  receiver,  and  the 

2)

general contactor will be locked. The LED 

 on the transmitter and receiver will start to flash and the 

S1 LED on the receiver will be activated, indicating that the radio control unit is in working mode. 

  From  this  moment,  if  any  button  is  pressed,  the  corresponding  operation  will  be  activated.  The 

3)

selected operation will remain active while the button is pressed. 

 

To keep the radio channel free and to avoid the operator could accidentally leave the machine on when it 
is not in use, the remote control is equipped with an automatic stop system. This system is activated after 
180  seconds  (it  can  be  programmed)  after  not  operating,  sending  a  stop  sequence  to  the  receiver, 
causing the machine to stop. 

Содержание IT3R10

Страница 1: ...User Manual MARI10EN Rev 1 05 2020 Receiver IT3R10 EN nS...

Страница 2: ...RODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITO...

Страница 3: ...RECEIVER 5 4 TECHNICAL SPECIFICATIONS 6 5 INSTALLATION AND START UP 7 5 1 INSTALLATION OF THE RECEIVER 7 5 1 1 FASTENING OPTIONS 7 5 2 CONNECTING 7 5 3 START UP 9 6 MAINTENANCE 10 6 1 MAINTENANCE OF...

Страница 4: ...y and at random thereby avoiding interferences which could cause continuous downtimes during operation The receiver works in the UHF band at frequencies between 433 050 and 434 775 MHz or between 868...

Страница 5: ...for each operation of the crane FM radio modulation and FFSK coding are used for radio transmission of control signals The control module is in charge of verifying that the information received is fr...

Страница 6: ...2 A to 250 Vac or 30 Vdc Power supply according to the model 48 Vac 230 Vac 20 15 according to EN 60047 5 1 48 Vac 115 Vac 20 15 seg n EN 60047 5 1 115 Vac 230 Vac 20 15 seg n EN 60047 5 1 24 Vac 230...

Страница 7: ...na it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS For the magnetic fastening option it should be placed on a met...

Страница 8: ...ATION AT TERMINALS 24 AND 26 1 This relay can be configured as N C Normally Close through the bridge located on the back of the board 2 For other power supplies please see the attached documents provi...

Страница 9: ...lowing steps will be done with the transmitter associated with the receiver Insert a charged battery into the transmitter set release the STOP BUTTON and press the START 1 button The remote control wi...

Страница 10: ...BEFORE HANDLING THE TRANSMITTER TURN OFF THE GENERAL SWITCH OF THE MACHINE 6 1 MAINTENANCE OF THE RECEIVER During maintenance of the receiver the following parts will be checked The connection between...

Страница 11: ...rting with LED S1 with the first digit of the code reading from left to right The following table indicates the correspondence between the hexadecimal value of each digit and the number of flashes tha...

Страница 12: ...STATE LED S2 Stand by mode or operation without changes Fault in Stop relays Flashing for each change of state in one of the relays STATE LED S3 Not used STATE LED S4 EEPROM Ok Error in EEPROM STATE...

Страница 13: ...to the electrical panel of the machine using the corresponding connectors The set is connected to the machine but it does not work The power supply of the set is under 45 of the nominal value The set...

Страница 14: ...ns avoiding possible negative consequences for the environment resulting from improper disposal And also allows a treatment and recycling of the materials that compose it obtaining important savings i...

Страница 15: ...RECEIVER IT3R10 USER MANUAL 15 www itowa com SINDITO S L Faraday 159 08224 Terrassa Barcelona Espa a Tel 34 93 733 98 50...

Отзывы: