RECEIVER IT3R10
USER MANUAL
8
The connection will be made through the terminal board that is screwed to the inside of the receiver
cover.
The below table indicates each operation and the terminals to be connected for the corresponding relay in
the standard receiver model:
¡ATTENTION!:
IF THE STOP OPERATION DOES NOT REQUIRE INDEPENDENT
CONTACTS, A JUMPER MUST BE DONE BETWEEN TERMINALS 23 AND 25 AND
CONNECT THE OPERATION AT TERMINALS 24 AND 26
1
This relay can be configured as N.C. (Normally Close) through the bridge located on the back of the
board.
2
For other power supplies, please see the attached documents provided with the receiver.
OPERATION
RELAY
Y
CONNECTOR PIN
Up
1
Down
2
Trolley left
3
Trolley right
4
Crane
forward
5
Crane
backward
6
2nd Speed
Hoisting
7
2ª Speed
Trolley
8
OPERATION
RELAY
CONNECTOR PIN
2nd Speed
Crane
9
Start / Horn
10
(1)
Stop 1
11
Stop 2
12
(2)
Fig. 5-1. Connection of relays and associated operations of the standard receiver.
View of the unscrewed terminal block of
the housing cover.
Terminal numbering.