![ITOH DENKI POWER MOLLER HBM-604BN Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/itoh-denki/power-moller-hbm-604bn/power-moller-hbm-604bn_technical-document_2095761024.webp)
Specifications subject to change without notice
ITOH DENKI USA, INC
135 Stewart Road
rev15-0115
PH: 570-820-8811
Hanover Industrial Estates
FX: 570-820-8838
Wilkes-Barre, PA 18706-1462
Page 24 of 25
Handshake signals between HBM-604BP and IB-E03BP
The cards are in standard orientation.
0V
SEN
24V
S
en
so
r
A
Port
P
o
w
er
A
M
O
TO
R
A
Port
B
24V
SEN
0V
S
e
ns
o
r B
1
D
IR
/R
S
T
2
A
U
TO
/M
A
N
U
3
N
P
N
/P
N
P
O
U
T
4
Z
P1
/Z
P
2
5
D
IR
C
T
IO
N
A
6
D
IR
C
T
IO
N
B
7
Z
O
N
E
2
/1
8
E
R
R
O
N
/P
LS
1
S
E
N
/S
Y
N
A
2
S
E
N
/S
YN
B
3
S
TO
P
/R
U
N
A
4
S
TO
P
/R
U
N
B
M
O
TO
R
B
PWR
I/O
C
T
R
L
S
E
N
A
S
E
N
B
0V
24V
<< Downstream IB-E03B
Upstream >>
Photo-sensor
Photo-sensor
<< Product Flow
P
M
4
8 6 F E-
6
0
P
M
4
8 6 F E -
6
0
1 S
E
N
/S
Y
N
A
2 S
E
N
/S
Y
N
B
3 S
T
O
P
/R
U
N
A
4 S
T
O
P
/R
U
N
B
C
T
R
L
S
E
N
A
S
E
N
B
1 D
IR
/R
S
T
2
A
U
T
O
/M
A
N
U
3 N
P
N
/P
N
P
O
U
T
4 Z
P
1/Z
P
2
5 D
IR
C
T
IO
N
A
6 D
IR
C
T
IO
N
B
7 Z
O
N
E
2/
1
8 E
R
R
O
N
/P
LS
12
3
4
5
678
9A
B
C
D
EF
0
1 2
3
4
5
678
9A
B
C
D
EF
0
C O M
O U T 5
O U T 4
O U T 3
O U T 2
O U T 1
R
e
m
o
te
O
U
T
A L M
0 V
S E N
2 4 V
S
e
n
s
o
rB
2 4 V
P
o
w
e
r
S E N
0 V
A L M
I N 1
I N 2
I N 3
C O M
0 V
2 4 V
R
e
m
o
te
IN
S
e
n
s
o
rA
M
O
T
O
R
A
M
O
T
O
R
B
L
A
N
1
L
A
N
2
1
0
0
B
A
S
E
-T
1
0
B
A
S
E
-T
E
th
e
rn
e
t
S
e
n
A
M
S
L
A
N
1
S
e
n
B
IN
1
O
U
T
1
O
U
T
2
O
U
T
3
O
U
T
4
O
U
T
5
IN
2
IN
3
L
A
N
2
N
S
1
S
T
S
M
O
TO
R
A
M
O
T
O
R
B
M
ot
or
/O
ut
pu
t
M
ot
or
/O
ut
pu
t
P
ow
er
N
od
e
ID
1.
M
A
-D
IR
2.
M
B
-D
IR
3.
M
A
-S
Y
N
4.
M
B
-S
Y
N
H
i
Lo
w
0V
+24V DC
Photo-sensor
Photo-sensor
P
M
4
8 6 F E -
6
0
P
M
4
8 6 F E-
6
0
1 2
3
4
5
678
9A
B
C
D
EF
0
1 2
3
4
5
678
9A
B
C
D
EF
0
N
od
e
ID
1.
M
A
-D
IR
2.
M
B
-D
IR
3.
M
A
-S
Y
N
4.
M
B
-S
Y
N
H
i
Lo
w
A HBM-604B can handshake signals to the IB-E03B and IB-E04F. Product will accumulate at the last zone before the IB
card. When ready the IB sends a force run signal to the HBM-604B to release product downstream. If a HBM-604 has an
error, the error output signal is pulsed from the HBM-604B to the IB card which can determine the error condition and
bring it to upper level Ethernet communication.
Set up:
•
Both cards are in standard orientation
•
No communication cable is in CN302 to force accumulation at photo sensor A on CN301.
•
On the HBM set DIP switch SW1-8 to ON for pulsed error output
•
On the HBM set DIP switch SW2-3 to ON for forced run motor A
•
On the IB card there are no DIP switch settings necessary and the card remains in standard orientation
Wiring:
•
Connect CN4-4 on the HBM card to Remote Input 1 on the IB card
•
Connect CN4-2 on the HBM card to a Remote Output on the IB card*
•
When using an HBM-604BP connect both commons on Remote Input and Remote Output on the IB card to 0V or
when using an HBM-604BN connect both commons on Remote Input and Remote Output on the IB card to +24V
*Any remote output on the IB card can be used according to your specific program or controller