ITOH DENKI POWER MOLLER HBL-606FN Скачать руководство пользователя страница 10

                                                                                                                              

  

 

 

 

 

Specifications subject to change without notice 

 
 

ITOH DENKI USA, INC 

 

135 Stewart Road 

 rev15-0615 

PH:  570-820-8811 

Hanover Industrial Estates 

FX:  570-820-8838 

Wilkes-Barre, PA  18706-1462 

Page 10 of 26 

Switch Settings 

 

Input / Output Settings SW1 

 

DIP 

Switch 

Function 

ON 

OFF 

Default 
Setting 

1-1 

Error Reset or Direction input 

Error reset 

Direction  

OFF 

1-2 

Error recovery 

Manual 

Automatic 

ON 

1-3 

PNP or NPN output 

PNP 

NPN 

ON 

HBL-606FP

 

OFF 

HBL-606FN

 

1-4 

ZPA release mode 

Train / Slug 

Singulated 

OFF 

1-5 

Motor A direction 

Based on MDR type 

Based on MDR type 

ON 

1-6 

Motor B direction 

Based on MDR type 

Based on MDR type 

ON 

1-7 

Zone count 

One zone  

Two zones 

OFF 

1-8 

Error output function 

Pulsed  

Signal when error occurs 

OFF 

 
DIP switch 1-1 – Error Reset or Direction 

 

Error Reset (RST; ON) 

o

  When the signal is applied then removed it resets an error(s) on all cards connected by communication 

cables 

 

Direction (DIR; OFF) [Default] 

o

  Reverses the logic and motor direction while signal is applied to all cards connected by communication 

cables 

 

SW 1-5 and 1-6  only change motor direction and do not change logic direction 

 

If both signals need to be used 

o

  Set DIP switch 1-1 ON for one card and input the RST signal to CN4-1 on the same card 

o

  Set DIP switch 1-1 OFF for another card and input the DIR signal to CN4-1 on the same card 

DIP switch 1-2 – Error recovery 

 

Manual recovery (MANU; ON) [Default] 

o

  Some form of user intervention is needed to reset if the card is in thermal protection 

o

  The temperature of the motor or card must be in operating range in order for the recovery to work 

o

  Remove power (CN1) to the card, then reapply – most likely case 

o

  Input then remove a signal to CN4-1 and have DIP switch 1-1 set ON for Error Reset (RST) 

 

This will send an error reset signal through all cards connected by communication cables 

o

  Input a signal to CN4-2 and have DIP switch 2-3 set ON for forcible run for errors on motor A 

 

This will reset errors for motor A 

o

  Input a signal to CN4-3 and have DIP switch 2-4 set ON for forcible run for errors on motor B 

 

This will reset errors for motor B 

 

Automatic recovery (AUTO; OFF) 

o

  The card will automatically reset the thermal protection once it or the motor has cooled to operating 

temperature.  

o

  This will also reset a low voltage error once the voltage becomes stable 

DIP switch 1-3 – Output signal type for both CN4-5 (OUT A) & CN4-6 (OUT B)  

 

PNP (ON) [Default on HBL-606FP] 

o

  When active the output will be +24V DC 

 

Do not connect to a low impedance input, 0V, or GND 

 

NPN (OFF) [Default on HBL-606FN] 

o

  When active the output will be 0V DC 

 
 
 
 
 
 
 

Содержание POWER MOLLER HBL-606FN

Страница 1: ...overheating stall condition and overspeeding Lead free design for RoHS conformity Logic for general zero pressure accumulation ZPA is built in o Singulated release o Slug train release with Flexible...

Страница 2: ...al Information 3 Dimensions 3 User Interface 3 Standard Conveyor Configuration 3 Connections 4 Installation Precautions Please read before installation 8 Switch Settings 10 Input Output Settings 10 Sp...

Страница 3: ...24V Sensor A Port Power A MOTOR A Port B 24V SEN 0V Sensor B 1 DIR RST 2 AUTO MANU 3 NPN PNP OUT 4 ZP1 ZP2 5 DIRCTION A 6 DIRCTION B 7 ZONE 2 1 8 ERR ON PLS 1 SEN SYN A 2 SEN SYN B 3 STOP RUN A 4 STO...

Страница 4: ...or A synchronization or sensor output selectable on SW2 1 6 Motor B synchronization or sensor output selectable on SW2 2 CN301 CN401 3 PIN connector for Photo Sensor Female Connector for Wiring WAGO 7...

Страница 5: ...motor A when sensor A becomes blocked while signal is active CN4 3 Input B selectable by SW2 4 see page 12 Forcible run motor B input SW2 3 ON Default o Forcibly runs motor B while signal is active Fo...

Страница 6: ...age 6 of 26 Connections continued CN302 CN402 8 PIN connector for Communication Cable Female Connector for Wiring RJ 45 CN302 CN402 Description 1 Error status Wire size 26AWG or Equivalent 8 wire cabl...

Страница 7: ...X 570 820 8838 Wilkes Barre PA 18706 1462 Page 7 of 26 Connections continued CN101 CN201 3 PIN connector for Motor Male Connector on Card JST S3B XH A Female Connector for Wiring JST XHP 3 PIN Descrip...

Страница 8: ...y because of moving rollers and transported articles Using as a slave card be sure the timer switch SW5 to zero 0 for slave mode This eliminates all timer functions and communication Roller s will not...

Страница 9: ...ame potential reference as earth ground Standard grounding practices should be followed Static discharge may interfere with general logic processing and in possibly damage IC components on the circuit...

Страница 10: ...input the RST signal to CN4 1 on the same card o Set DIP switch 1 1 OFF for another card and input the DIR signal to CN4 1 on the same card DIP switch 1 2 Error recovery Manual recovery MANU ON Defaul...

Страница 11: ...g ON OFF 1 5 Motor A direction ON CW CCW ON OFF CCW CW 1 6 Motor B direction ON CW CCW ON OFF CCW CW Motor direction as viewed from the cable side PM486 series is independent of ZPA logic flow directi...

Страница 12: ...a signal on CN4 6 when sensor B is blocked DIP switch 2 3 Motor A input function Forcible STOP OFF o Prevents an article from advancing downstream once motor A s zone while receiving the signal becom...

Страница 13: ...setting for Motor B Used to vary the speed on motor B PM486LE LD 80 Rotary Switch SW3 SW4 Speed m min 3 ft min 3 9 80 262 5 8 70 229 7 7 60 196 9 6 50 164 0 5 45 147 6 4 40 131 2 3 35 114 8 2 30 98 4...

Страница 14: ...the present zone Sensor Timer starts when o Present zone is running due to the condition above o AND the upstream zone s photo sensor becomes clear If a jam occurs in the upstream zone Sensor Timer n...

Страница 15: ...stream zone s photo sensor becomes blocked Initial startup seek to sensor time is the same as the jam timer value ZPA will not begin until this time expires Other Settings Slave Mode 3 STOP RUN A 4 ST...

Страница 16: ...1 DIR RST 2 AUTO MANU 3 NPN PNP OUT 4 ZP1 ZP2 5 DIRCTION A 6 DIRCTION B 7 ZONE 2 1 8 ERR ON PLS 1 SEN SYN A 2 SEN SYN B 3 STOP RUN A 4 STOP RUN B MOTOR B PWR I O CTRL SEN A SEN B 0V 24V PWR STS A MOT...

Страница 17: ...6Hz ON Fuse blown or low voltage No operation 1 OFF Blinks 1Hz ON Motor is not connected to card No operation 2 ON Blinks 1Hz ON Motor locked 1s No operation 3 OFF ON ON Thermal protection No operatio...

Страница 18: ...n under Input Output settings DIP switch 1 2 If the voltage is a stable 24V DC power then the fuse has blown and the card must be replaced 2 Motor unplugged Check motor ports to ensure the motor conne...

Страница 19: ...view Connections CN4 and Input output settings DIP switch 2 3 and 2 4 6 Sensor signal ON Should be on only when the photo sensor is blocked If it is on when the zone is clear then it is the incorrect...

Страница 20: ...ZONE 2 1 8 ERR ON PLS 1 SEN SYN A 2 SEN SYN B 3 STOP RUN A 4 STOP RUN B MOTOR B PWR I O CTRL SEN A SEN B 0V 24V Downstream Upstream Photo sensor 0V PS Output 24V DC Photo sensor 0V PS Output 24V DC Pr...

Страница 21: ...TOP RUN A 4 STOP RUN B CTRL SEN A SEN B 1 DIR RST 2 AUTO MANU 3 NPN PNP OUT 4 ZP1 ZP2 5 DIRCTION A 6 DIRCTION B 7 ZONE 2 1 8 ERR ON PLS Photo sensor Infeed The infeed zone can use 2 photo sensors 1 Ma...

Страница 22: ...gnal Discharge zone is applied when an article is to accumulate once it reaches the last HBL zone Without a communication cable connected to CN301 in the default direction or CN402 when the direction...

Страница 23: ...8 ERR ON PLS 1 SEN SYN A 2 SEN SYN B 3 STOP RUN A 4 STOP RUN B MOTOR B PWR I O CTRL SEN A SEN B 0V 24V Downstream Upstream Photo sensor 0V PS Output 24V DC Product Flow P M 4 8 6 L D 8 0 1 SEN SYN A...

Страница 24: ...PLS 1 SEN SYN A 2 SEN SYN B 3 STOP RUN A 4 STOP RUN B MOTOR B PWR I O CTRL SEN A SEN B 0V 24V Downstream Upstream Photo sensor 0V PS Output 24V DC Product Flow P M 4 8 6 L D 8 0 Product Flow P M 4 8...

Страница 25: ...nsor P M 4 8 6 F E 6 0 P M 4 8 6 F E 6 0 1 2 3 4 5 6 7 8 9 A B C D E F0 1 2 3 4 5 6 7 8 9 A B C D E F0 Node ID 1 MA DIR 2 MB DIR 3 MA SYN 4 MB SYN Hi Low A HBL 606F can handshake signals to the IB E03...

Страница 26: ...ice ITOH DENKI USA INC 135 Stewart Road rev15 0615 PH 570 820 8811 Hanover Industrial Estates FX 570 820 8838 Wilkes Barre PA 18706 1462 Page 26 of 26 Revision History Revision Number Change Created B...

Отзывы: