background image

198.5

55.8

15.7

194.8

54.7

15.4

192.3

54.0

15.2

183.1

51.4

14.4

174.0

48.9

13.7

164.8

46.3

13.0

146.5

41.1

11.6

137.3

38.6

10.8

128.2

36.0

10.1

119.0

33.4

9.4

109.8

30.9

8.7

100.7

28.3

7.9

91.5

25.7

7.2

82.4

23.1

6.5

73.3

20.6

5.8

64.1

18.0

5.1

54.9

15.4

4.3

45.8

12.9

3.6

36.6

10.3

2.9

27.5

7.7

2.2

240.2

67.5

19.0

235.8

66.2

18.6

232.6

65.4

18.4

221.6

62.2

17.5

210.5

59.1

16.6

199.4

56.0

15.7

177.2

49.8

14.0

166.2

46.7

13.1

155.1

43.6

12.2

144.0

40.4

11.4

132.9

37.3

10.5

121.8

34.2

9.6

110.8

31.1

8.7

99.7

28.0

7.9

88.6

24.9

7.0

77.6

21.8

6.1

66.5

18.7

5.2

55.4

15.6

4.4

44.3

12.5

3.5

33.2

9.3

2.6

259.0

57.0

15.1

259.0

57.0

15.1

259.0

57.0

15.1

254.0

55.9

14.8

241.3

53.1

14.1

228.6

50.3

13.3

203.2

44.7

11.8

190.5

41.9

11.1

177.8

39.1

10.4

165.1

36.3

9.6

152.4

33.5

8.9

139.7

30.7

8.1

127.0

27.9

7.4

114.3

25.1

6.7

101.6

22.3

5.9

88.9

19.6

5.2

76.2

16.8

4.4

63.5

14.0

3.7

50.8

11.2

3.0

38.1

8.4

2.2

6

7

PM500FE

PM500FS/PM500FP

PM605FE

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

210

60

17

*1  

Consult local ITOH DENKI representative in case you use MDR with 

         nominal 

speed not in the above table.

*2  

It is not available for Low temperature applications(LT)

*3  

It is not available at temperatures of -30 to 

0

 degrees or less for LT.

  

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

210

60

17

9.6〜9.9

9.1〜9.4

8.6〜8.9

8.1〜8.4

7.6〜7.9

7.1〜7.4

6.6〜6.9

6.1〜6.4

5.6〜5.9

5.1〜5.4

4.6〜4.9

4.1〜4.4

3.6〜3.9

3.1〜3.4

2.6〜2.9

2.1〜2.4

1.6〜1.9

1.1〜1.4

0.6〜0.9

0.1〜0.4

255

55

15

O N

O F F

O N

O F F

O N

O F F

SW1-5

SW 5

MDR Nominal Speed (m/min) 

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*3

*3

*3

*3

*3

SW1-5

SW 5

MDR Nominal Speed (m/min) 

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*3

*3

*3

*3

*3

SW1-5

SW 5

MDR Nominal Speed (m/min) 

Internal speed variation

 input

Analog voltage

Speed dev/-3%

*1

*2

*3

*3

*3

*3

*3

*3

5-2  Direction Setting 

5-3  Acceleration and Deceleration

Reverse direction by external DIR signal can be permitted even while motor is running.
MDR turning direction can be set or changed either internally by integral dip switch or  
externally by optional switch.  

Disregard the error signal discharged when power is injected to the driver card 

(for 0.5 sec) and when power to the driver card is shut off (for 2 seconds)  

Error signal is discharged from CN2-4

6  Error Signal Output 

SW1-4 allows the selection of the error signal discharge timing: discharge on normal status or 
discharge when error arises.  Error signal is NPN open collector in cace of CB-016N6/BN6.

See section 8 for error status, reset and history.

 ●

To monitor the error signal, a protective resistor should be mounted to  

  

suppress 24VDC to 25mA or less.  

 ●

The driver card has 100

Ω

 protective resistor. 

Integral potentiometer VR 1 allows the acceleration adjustment from 0 to 2.5 seconds.
Integral potentiometer VR 2 allows the deceleration adjustment from 0 to 2.5 seconds. 


* 

Turning direction viewed from the MDR's power cable side.

* 

0V should be common to power voltage.

* 

3mA current is drawn at CN2-2 

Reverse direction by DIP switch is prohibited while motor is running. Motor must be
stopped first, and then reverse a direction by DIP switch.

VR(1)

VR(2)

SW1-4 ON

SW1-4 OFF

Error signal discharges in normal status

Error signal discharges when error arises

Open on error

Open on normal

FE 

type

FS/FP 

type

ON

S W 1 - 3

OFF

The adjustable range of time is on the control basis, thus may differs on actual 

    transfer speed. 

Setting for Turning Direction 

CW/CCW

Reverse motor direction by external DIR signal.

CW

CCW

CW

CCW

CCW

CW

CCW

CW

Open contact 

CW/CCW

Close contact  

CW/CCW

Open contact 

CW/CCW

Close contact  

VR1

VR2

1

2

3

4

5

R U N

S TO P

O N

O F F

C N2#2

Reverse

Normal

Deceleration setting time (VR2)

Turning direction

Acceleration setting time (VR1)

0 . 5 S

1

2

3

4

5

ERR

V-IN

RUN

DIR

1234

ERR

V-IN

RUN

DIR

1234

ERR

V-IN

RUN

DIR

1234

ERR

V-IN

RUN

DIR

1234

Set speed

RUN signal

 Input  

Stop signal

 Input  

0 sec

2.5 sec

min

max

Caution

Содержание CB-016 series

Страница 1: ...he signal may stay ON or OFF in case of the CB 016 driver card failure Be sure to shut off the power before inserting or removing any connector Do not wire connector left in the CB 016 driver card Do...

Страница 2: ...arks See section 5 3 Dip Switch SW1 Min Default Acceleration from RUN signal 0 sec 2 Deceleration from STOP signal 0 sec 2 5 sec 2 5 sec Min Min Potentiometer VR Model Model nomenclature To the CCW en...

Страница 3: ...R shafts are adequately secured with the supplied brackets or accessories Each connector on the driver card is adequately wired and inserted Operating and environmental conditions are respected Power...

Страница 4: ...Nominal Speed m min Internal speed variation input Analog voltage Speed deviation 3 1 2 3 3 3 3 3 3 5 2 Direction Setting 5 3 Acceleration and Deceleration Reverse direction by external DIR signal ca...

Страница 5: ...ect signal RUN STOP RUN order to CN2 1 Inject signal RUN STOP RUN order to CN2 1 Restarts automatically in a minute After thermister recovery inject signal ON OFF ON or OFF ON OFF order to CN2 2 After...

Страница 6: ...thermister error thermister error under voltage error under voltage error under voltage error first time second time 3 times thermister error under voltage error thermister error first time second ti...

Страница 7: ...ww itohdenki com Asia Oceania Itoh Denki Asia Limited Phone 852 2427 2576 Fax 852 2427 2203 China Itoh Denki Shanghai Company Limited Phone 86 21 6341 0181 Fax 86 21 6341 0180 www itohdenki com cn 4 6...