Itm AIRFLOW TA410 Скачать руководство пользователя страница 3

 

Copyright

 

TSI Incorporated / 2007-2020 / All rights reserved. 

Limitation Of Warranty And Liability

 (effective February 2015) 

Seller warrants the goods, excluding software, sold hereunder, under normal use and 
service as described in the operator's manual, to be free from defects in workmanship 
and material for 

24 months

, or if less, the length of time specified in the operator's 

manual, from the date of shipment to the customer. This warranty period is inclusive of 
any statutory warranty. This limited warranty is subject to the following exclusions and 
exceptions:   

a. Hot-wire  or  hot-film  sensors  used  with  research  anemometers,  and  certain  other 

components when indicated in specifications, are warranted for 90 days from the date of 
shipment;  

b. 

Pumps  are  warranted  for  hours  of  operation  as  set  forth  in  product  or  operator’s 
manuals; 

c.  Parts  repaired  or  replaced  as  a  result  of  repair  services are warranted to be free from 

defects  in  workmanship  and  material,  under  normal  use,  for  90  days  from  the  date  of 
shipment;  

d. Seller  does  not  provide  any  warranty  on  finished  goods  manufactured  by  others  or  on 

any  fuses,  batteries  or  other  consumable  materials.  Only  the  original  manufacturer's 
warranty applies; 

e. This warranty does not cover calibration requirements, and seller warrants only that 

the instrument or product is properly calibrated at the time of its manufacture. 
Instruments returned for calibration are not covered by this warranty;   

f.  This warranty is 

VOID

 if the instrument is opened by anyone other than a factory 

authorized service center with the one exception where requirements set forth in the 
manual allow an operator to replace consumables or perform recommended 
cleaning;   

g. This warranty is 

VOID

 if the product has been misused, neglected, subjected to 

accidental or intentional damage, or is not properly installed, maintained, or cleaned 
according to the requirements of the manual.Unless specifically authorized in a 
separate writing by Seller, Seller makes no warranty with respect to, and shall have no 
liability in connection with, goods which are incorporated into other products or 
equipment, or which are modified by any person other than Seller.  

The foregoing is 

IN LIEU OF

 all other warranties and is subject to the 

LIMITATIONS

 

stated herein. 

NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR 

PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO 
SELLER’S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, 
SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND 
EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. 
BUYER’S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE 
PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR O

R AT SELLER’S 

OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.

  

TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER 
OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, 
INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS 
BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR 
OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND 
OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR 

www.

.com

[email protected]

1.800.561.8187

Содержание AIRFLOW TA410

Страница 1: ...AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410 OPERATION AND SERVICE MANUAL P N 1980575 REV G NOVEMBER 2020 www com information itm com 1 800 561 8187 ...

Страница 2: ...www com information itm com 1 800 561 8187 ...

Страница 3: ...nt is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning g This warranty is VOID if the product has been misused neglected subjected to accidental or intentional damage or is not properly installed maintained or cleaned according to the requirement...

Страница 4: ...Seller s risk of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limited warranty of Seller This LIMITATION OF WARRANTY AND LIABILITY may not be amended modified or its terms waived except by writing signed by an Officer of Seller Service Policy Knowing that inoperative or defective instruments are as detrimen...

Страница 5: ...low Instruments TA410 3 Installing the Batteries 3 Using The Telescoping Probe 3 Extending The Probe 3 Retracting The Probe 3 CHAPTER 3 OPERATION 5 Keypad Functions 5 CHAPTER 4 MAINTENANCE 7 Recalibration 7 Cases 7 Storage 7 CHAPTER 5 TROUBLESHOOTING 9 APPENDIX A SPECIFICATIONS 11 www com information itm com 1 800 561 8187 ...

Страница 6: ... the instrument and accessories from the shipping container Check the individual parts against the list of components below If anything is missing or damaged notify TSI Incorporated immediately 1 Carrying case 2 Instrument www com information itm com 1 800 561 8187 ...

Страница 7: ...ger of battery acid leakage Using the Telescoping Probe The telescoping probe contains the velocity and temperature sensors When using the probe make sure the sensor window is fully exposed and the orientation dimple is facing upstream NOTE For temperature measurements make sure that at least 3 inches 7 5 cm of the probe is in the flow to allow the temperature sensor to be in the air stream Extend...

Страница 8: ...n and Last Date Calibrated ft min m s Key Pressing this key changes the display to read air velocity C F Key Pressing this key changes the display to read temperature Changing Units To change units first put the desired measurement air velocity or temperature on the display Then press and hold the left unlabelled key for five seconds Finally use the and ENTER key to select the units www com inform...

Страница 9: ... number To fill out an online Service Request form visit TSI s website at U S International UK TSI Incorporated TSI Instruments Ltd Alnor Products Cases If the instrument case or storage case needs cleaning wipe it off with a soft cloth and isopropyl alcohol or a mild detergent NEVER immerse the Alnor AVM410 Airflow Instruments TA410 If the enclosure of the Alnor AVM410 Airflow Instruments TA410 b...

Страница 10: ... Corrective Action No Display Unit not turned on Switch unit on Low or dead batteries Replace batteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent flow Instrument Error message appears Fault in instrument Factory service required on instrument W A R N I N G Remove the probe from ex...

Страница 11: ...F 18 to 93 C Storage 4 to 140 F 20 to 60 C External Meter Dimensions 3 3 in 7 0 in 1 8 in 8 4 cm 17 8 cm 4 4 cm Meter Weight Weight with batteries 0 6 lbs 0 27 kg Power Requirements Four AA size batteries included 1 Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C 2 The accuracy statement of 5 0 of reading or 5 ft min 0 025 m s whichever is greater begins at 30 ft min...