ITI 60-744 Скачать руководство пользователя страница 3

3

SAW Learn Mode Water Sensor

Installation

4.

Exit from dealer sensor test mode.

Test Sensor Operation

1.

Make sure the Water Sensor is in the secure (non-
alarm, dry) state.

2.

Place the control panel into sensor test mode.

3.

Trip the sensor by shorting across the detector by wrap-
ping the wire around the two contact points (see Figure 
3).

4.

Listen for the appropriate siren response as described in 
the panel installation instructions.

5.

Remove the wire from the two detector contact points 
to send a restore signal to the panel.

6.

Exit from sensor test mode.

Installation

Permanently install the Water Sensor only after program-
ming and testing it.

Note

Once the sensor has been installed it is recom-
mended that you test the sensor range.

To install the Water Sensor 

without

 using screws:

1.

Prepare a clean, dry mounting surface for the detector 
and transmitter.

2.

Secure the detector to the mounting surface using the 
double-faced tape (included).

3.

Secure the Water Sensor transmitter to the mounting 
surface using the double-faced tape.

Figure 4. Installing the Water Sensor 

without

 Screws

To install the Water Sensor using screws:

1.

Prepare a clean, dry mounting surface for the detector.

2.

Secure the detector to the mounting surface using the 
double-faced tape (included).

3.

Remove the Water Sensor transmitter outer cover by 
pressing the round button on the end of the transmitter 
(see Figure 2).

4.

Remove the batteries from the transmitter to access the 
screw mounting hole underneath them.

5.

Use the included #6 pan head screws to secure the 
transmitter to the mounting surface. If mounting on 
plaster, use the appropriate fasteners. Use the slotted 
mounting hole for alignment (see Figure 5).

Figure 5. Installing the Water Sensor 

with

 Screws

6.

Replace the batteries.

7.

Replace the transmitter outer cover.

Отзывы: