Page 4
Power Up and Bus Communication
This section describes how to power up the panel and
the ESM and get them communicating with each other.
To power up the UltraGard panel and the ESM:
1.
Verify that all wiring at the panel and the ESM are
correct.
2.
Reconnect the panel battery and plug in the power
transformer.
3.
Turn on the panel power switch.
4.
Set the panel’s RUN/PROGRAM switch to
PROGRAM.
If the alphanumeric display reads
1-OFF
and the
1
is flashing, you must enter the install code (4-digit
installer access code) to get the panel into the pro-
gram mode.
The alphanumeric display should read
PROGRAM
MODE
and the ESM LED should be flashing con-
tinuously, indicating successful communication to
the panel.
Note:
If the LED is not flashing continuously, set the
RUN/PROGRAM switch to RUN and turn off the
panel power switch. Verify that all wiring is cor-
rect and that all bus devices are set with different
unit ID numbers.
Whenever the ESM unit ID number is changed,
you must turn off the panel power switch, turn it
back on, and then enter the program mode for
the panel and ESM to communicate successfully.
Setting the ESM SET TEMP
The SET TEMP programming command lets you adjust
the ESM temperature so it matches the house thermostat
reading. Refer to the specific panel’s installation
instructions for complete details.
Note:
The ESM must be installed and powered up for a
minimum of 15 minutes before adjusting the ESM
temperature, to ensure consistent readings
between the ESM and house thermostat.
For best results, wait an hour before adjusting the
ESM temperature as described in the specific
panel’s
reference manual
.
Programming and Testing the ESM
For complete ESM programming and testing information,
refer to the specific panel’s installation instructions.
Specifications
Compatibility: UltraGard
Power Requirements: 12 VDC, 30 mA (maximum)
Dimensions: 2.60" x 2.60" x.90" (L x W x D)
Notices
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may
cause undesired operation.
Changes or modifications not expressly approved by Interactive Technologies, Inc. can
void the users authority to operate the equipment
ITI is a registered trademark of Interactive Technologies, Inc. UltraGard is a trademark of
Interactive Technologies, Inc.