9
3.
Installation
3.1.
Installation requirements
Please observe the following before installation: Mount
the BTV:
●
At a height of 2.3 metres above the ground in the wall, or in
the ceiling (not in the floor or in a sloping wall!).
●
In a room where there is sufficient supply air.
●
in the vicinity of a 230 V, 50 Hz wall socket.
Ensure low resistances by using as many short, straight and
smooth ducts as possible. When using flexibles, we recommend
using a larger duct diameter. Also use a wall duct with low
resistance.
The fan is suitable for a connection diameter of 100 mm.
Placement against a connection diameter up to 125 mm is
possible, but may slightly affect performance.
Warning!
When using a cable tray, a suitable power cable with an outer
diameter of 5 to 7 mm must be passed through the rubber cable
duct and strain relief provided.
Warning!
Before starting the electrical installation (connecting the
wiring), de-energise the group to which the fan is connected.
Do not re-energise the group until AFTER the installation has
been completed.
Warning!
Never connect the device with an extension lead!
Warning!
Never connect the device with a damaged power cable!
3.2.
Installing the fan
The BTV-N200 series bathroom and toilet fan should be mounted in
the wall or the ceiling.
c) Drill the necessary holes for the plugs supplied. Use the rear
part of the fan itself as a marking template or use the
dimensional drawings.
Mount the fan as follows:
a)
Make sure that any remaining dirt is removed from the hole.
b)
Check whether there is a power supply connection at the
location where the fan is to be installed.
d)
Insert the supplied plugs.
Warning!
The duct to the outside must be leak-tight connected to the
fan and installed at a slope.
Warning!
The fan should discharge the exhaust air directly to the outside.
6 mm
Содержание 53-00350