11.6 Error messages and warnings
Group 0: Events
0-0
Invalid error
An invalid (corrupted) entry in the error buffer has been marked with this error
number. Entry in the permanent event memory. No measures required.
0-1
Invalid error detected and
corrected
An invalid (corrupted) error entry has been detected and corrected in the error
buffer. The debug information includes the original error number. Entry in the
permanent event memory. No measures required.
0-2
Error cleared
The active errors have been acknowledged.
Entry in the permanent event memory. No measures required.
0-4
Serial number / device type
(module replacement)
A replaceable error memory module (service module) has been plugged into
another device. Entry in the permanent event memory. No measures required.
0-7
Additional log entry
Entry in the permanent event memory. No measures required.
0-8
Servo drive switched on
Log entry proving that the servo drive has been switched on. Entry in the perma
-
nent event memory. No measures required.
0-9
Servo drive: safety parame
-
ters changed
Logging of the parameterisation of the FSM 2.0 - MOV. Entry in the permanent
event memory. No measures required.
0-11
FSM module replacement
(previous type)
Logging of the module replacement. Entry in the permanent event memory. No
measures required.
0-12
FSM-Modulwechsel
(neuer Typ)
Logging of the module replacement. Entry in the permanent event memory. No
measures required.
0-21
FSM module replacement
(current type)
Logging of events in the FSM. Entry in the permanent event memory. No measu
-
res required.
0-22
Default parameter set
loaded
Log entry proving that the default parameter set has been loaded. Entry in the
permanent event memory. No measures required.
Group 1: Stack overflow
1-0
Stack overflow
Incorrect firmware? Load the most recent firmware. Please contact the Techni
-
cal Support team.
Group 2: Undervoltage
2-0
Undervoltage of DC bus
circuit
Check the error handling settings (error management). Check the power supply
voltage. Check (measure) the DC bus circuit voltage. Check the response thres
-