Remote Operation
Copyright © Itech Electronic Co., Ltd.
18
the IT-E133 and computer with GPIB/IEEE 488 line for the communication.
The DB9 interface connector
on the rear panel of power supply can’t be
connected to PC by using standard RS-232, USB or GPIB cable. You must use
the communication module IT-E121, IT-E122 or IT-E133 to connect
4.2 Communication Between Power Supply and PC
Before using the remote operation mode, please make sure that the baud rate
and communication address in power supply are the same as in the computer
software, otherwise, the communication will fail, you can change the baud rate
and communication address from the front panel or from computer.
Baud rate: 4800,9600,19200 and 38400 are selectable, default setting is
9600
Data bit: 8 bit
Stop bit: 1
Parity: (none, even, odd)
Address
Start Bit
8 Data Bits
Parity=None
Stop Bit
Note
You can change the baud rate and communication address from the front panel or from
computer, but the data bite, stop bit and parity are the defaults and can’t be changed.
DB9 Interface Details
Power
Supply
GPIB
interface