IEEE-488 Commands
Copyright© Itech Electronic Co., Ltd.
46
Chapter10 IEEE-488 Commands
*CLS
This command clears the following registers:
⚫
Standard event register
⚫
Query event register
⚫
Operation event register
⚫
Status byte register
Command syntax
*CLS
Arguments
None
*ESE
This command can set the parameter of standard event enable register.
Setting parameter can determine which bit of standard event register is 1
and the byte will enable ESB of status byte register is 1.
Command syntax
*ESE <NRf>
Arguments
0~255
Default set
Refer to *PSC command
Example
*ESE 128
Query syntax
*ESE?
Returns
<NR1>
*ESR?
This command can read the value of standard event status register. After
executing this command, standard event status register is reset. Bit
definition of standard event status register is as the same as the
standard event status enable register.