3030 Corporate Grove Dr. • Hudsonville • MI • 49426
Phone: 616-396-1355 • www.itc-us.com • [email protected] • DOC#: 710-00131 Rev G • 02/17/21
5.
CUSTOMIZING YOUR SYSTEM:
There are several features that can be
selected using the four position dip switches on the back of the
control module. To adjust these switches, first remove the four screws
on the back.
Remove screws
MULTIPLE RGB CONTROLLERS ON SAME CAN
BUS NETWORK:
If you are using more than one controller on a
CAN network, you will need to adjust the CAN
address. Dip switch one and two are used to
select an address.
Switch 1
Switch 2
Address
OFF
OFF
0 (Default)
ON
OFF
1
OFF
ON
2
ON
ON
3
SELECT TO POWER UP IN THE ON OR OFF STATE:
Using dip switch four you can select if you
want the controller to power up in the OFF
state when power is applied, or in the ON
state once power is applied.
Switch 4
Power
OFF
Power up OFF (default)
ON
Power up ON
Dip switch
adjustment
RESET PASS CODE:
If needed, dip switch three can be switched
on and then off to reset the Bluetooth pass
code.
Switch 3
Pass Code
OFF
No change
ON
Reset pass code
6.
DISABLE/SIGNAL INPUT LINE (optional):
The control module has the ability to turn off zones if an input line to the controller is activated. If
the disable line is held at the input voltage (5-24 volts), Zones one and two will be turned off. This feature can be used if you want to
deactivate the zone lights on the outside of the boat when in motion. By default, only zones one and two are turned off. There is no
effect on zones three and four (if applicable). You can adjust which zones are turned off via a CAN interface display system.
8.
WIRING CONSIDERATIONS:
- Don’t power the controller or lights until all connections are made.
- It is recommended that strain relief be added on all wires to prevent any damage to the lights.
- If fuses are not included on the RGB controller then ITC recommends including fuses on each zone output (+) wire.
- If installing a flexible lighting product, do not install the end caps in the mounting track or it may damage the light.
- To test the lights, select the single color fade for each of the colors, red, green and blue on the VersiControl app. This test will show
whether there are wiring issues.
- For the NMEA2000 version controller, its LEN (Load Equivalency Number) equals two.
7.
AUDIO INPUT LINE (optional):
The controller has the ability to receive an audio input signal (Line Level) through the 3.5mm RCA audio
input female connector. It can use this signal to adjust the light brightness and color based on the audio signal strength and frequency.