An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be

 incorporated in

the electrical installation of the building.

When Installing the Unit

     Never  plug   in  nor remove the power  supply  plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging  the  power  supply cord, be sure
     to grasp the  power  supply  plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure to remove its power 
     supply cord  from the  wall  outlet.  Moving  the unit
     with the  power  cord  connected  to  the outlet may
     cause damage to the power cord, resulting in fire or 
     electric shock. When  removing the power cord,  be
     sure to hold its plug to pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating  sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do not place heavy objects on the unit as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power is 
    switched  on  can  impair  hearing.

     Do not operate  the  unit  for an  extended  period of 
     time with  the sound distorting. This  is   an indication
     of   a  malfunction,  which  in  turn   can cause heat to
     generate and result in a fire.

     Contact your 

 dealer as  to the  cleaning. If  dust 

    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

ITC 

  If dust accumulates on the power supply plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off  the   power, and unplug the power  supply
  plug   from the  AC outlet  for  safety  purposes when 
  cleaning  or   leaving the unit unused for  10  days or 
  more. Doing otherwise  may cause a fire  or   electric 
  shock.

SAFETY PRECAUTIONS

Содержание TS-231

Страница 1: ...IGH CUT 0 12 6 12 6 CH1 INPUT OUTPUT LEVEL CH2 INPUT OUTPUT LEVEL CHANNEL 2 20 80 100 5K 6 3K 8K 10K 12 5K 16K 20K 25 31 5 40 50 63 125 160 200 250 315 400 500 630 800 1K 1 25K 1 6K 2K 2 5K 3 15K 4K GRAPHIC EQUALIZER TS 231 INPUT 0 dB 7 7 12 12 5 5 60 Hz 150 240 10 25 15 85 LOW CUT 15 KHz 30 40 3 7 4 20 HIGH CUT INPUT 0 dB 7 12 12 7 5 5 CH1 CH2 6dB 12dB RANGE 6dB 12dB BYPASS EQ POWER POWER METER I...

Страница 2: ...ult in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unst...

Страница 3: ...ng sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched ...

Страница 4: ...TABLE OF CONTENTS 1 1 2 2 2 1 Front Panel 2 2 2 Rear Panel 2 3 3 4 5 5 6 FEATURES NOMENCLATURE AND FUNCTIONS OPERATION MACHINE CONNECTION DIAGRAM SPECIFICATIONS ...

Страница 5: ...sover frequency can be adjusted 9 Each channel can be switched on the high cut and low cut filter to get rid of annoying noise such as local noise and tape hiss etc 10 12 digit LED input output level extremely accurate with input gain control so you can control the level of proficiency 11 Low noise amplifier to operate a beautiful sound 12 Gold plated XLR connectors with 6 3 mm stereo jack and ser...

Страница 6: ...hrough regulation with the EQ button 10 2 way selection button level display 11 2 keys input signal conditioning 12 2 way frequency selector buttons 13 2 way high frequency selection buttons 14 2 way gain 6dB 12dB Button marked 6dB gain adjustment Button Lay 12dB gain adjustment 2 1 Front Panel 2 2 Real Panel 2 NOMENCLATURE AND FUNCTIONS 910 11 12 13 14 5 4 3 2 1 6 8 CHANNEL 1 0 12 6 12 6 RANGE 60...

Страница 7: ... thorough sound bright low sound dim Improve over the phone when you have a similar sound Alt 2KHz 5KHz the strings and the characteristics of sound pull string in the bow and the string sound of the friction and shoving playing the pull string music the sound of a finger Insufficient penetration of the sound down too strong language when masking syllable recognition Treble 7KHz 8KHz is the layeri...

Страница 8: ...translucent 2800Kz luminosity relation near the maximum 2K 4Kz the formation of sharp 6800Hz wailing sharp feeling 4K 8Kz crisp 3400Hz easily cause hearing fatigue 8K 16Kz slim gt 7 5KHz pitch Qingche fine The development trend of the equalizer The use of digital filter called the equalizer consisting of digital equalizer digital equalizer can be made icons EQ there can be made parametric EQ you c...

Страница 9: ... LED PWR MIC INPUT 1 3 5 6 7 1 3 6 GAIN MIC 4 GAIN GAIN GAIN MIC 3 MIC 2 MIC 1 DC 24V OUTPUT EMC INPUT REC AUX1 AUX2 AUX3 48V PHANTOM MIC1 MIC2 MIC3 MIC4 OFF ON ON OFF ON OFF ON OFF 2 1 3 4 MACHINE CONNECTION DIAGRAM After the pure power amp ON OFF USE ONLY WITHA 250W FUSE CHANNEL 2 OUTPUT CHANNEL 2 INPUT CHANNEL 1 OUTPUT CHANNEL 1 INPUT 1 2 3 PUSH 1 2 3 PUSH 5 ...

Страница 10: ...e frequency points Line output Frequency response Gain attenuation adjustment range Power Power consumption Machine size Net weight A group of three A group of three 20Hz 20kHz 3 dB 1 25 31 points octave 12 dB 484X128X88 AC 220 240V 50 60Hz 70W 3 5Kg 6 ...

Страница 11: ...PUBLIC ADDRESS SYSTEM VersionV0 4 ...

Отзывы: