background image

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

  If dust accumulates on the power supply  plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off   the  power, and unplug the power   supply
  plug   from the  AC outlet   for  safety   purposes when 
  cleaning   or  leaving the unit unused for   10  days or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

When the Unit is in Use

     Do not place heavy objects on the unit  as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

    Contact your 

 dealer  as  to  the   cleaning.  If  

    dust is  allowed  to accumulate  in  the  unit  over  a  
     long period of   time, a  fire   or  damage   to  the   unit 
    may  result.

 ITC

2 . AT T E N T I O N

2

Содержание T-1S01

Страница 1: ...E AMPLIFIER PUBLIC ADDRESS SYSTEM POWER TREBLE AUX 1 AUX 2 AUX 3 MIC 2 MIC 3 MIC 4 MIC 5 BASS 5 0 1 2 3 4 6 7 8 9 10 0 5 4 3 2 1 1 2 3 4 5 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7...

Страница 2: ...TIONS 6 OPERATION ILLUSTRATION 6 1 6 2 6 3 6 4MIC 2 5 balanced microphone MIC 2 4 unbalanced input and the GAIN 6 5 48 phantom power selector switch 6 6 EMC input 6 7 AUX 1 3 auxiliary inpu 6 8 6 9 6...

Страница 3: ...in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electr...

Страница 4: ...ting sooty smoke or steam as doing otherwise may result in fire or electric shock If dust accumulates on the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addit...

Страница 5: ...meet the requirements from mini to medium Public address system Pre amplifier is connector with various audio sources including comm on audio sources such as CD player tuner fire alarmgeneral erator...

Страница 6: ...9 10 CHIME 5 0 1 2 3 4 6 7 8 9 10 ON OFF 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 MASTER 5 0 1 2 3 4 6 7 8 9 10 0 5 4 3 2 1 1 2 3 4 5 5 FUNCTIONS Front Panel 2 3 4 7 9 1 5 8 6 1 Electricity Indic...

Страница 7: ...2 3 4 1 2 3 1 2 3 1 2 3 1 2 3 10 11 19 FUNCTIONS Rear Panel 12 13 14 15 16 17 18 20 10 Mic1 insert connects with T 319 11 Mic 2 5 balance XLR mic input 12 Mic 2 5 phantom 48V power option switch 13 E...

Страница 8: ...or light red out The switch can not control the 24V switch 6 3 Mic1 EXT microphone input POWER ON OFF 2 Fig 6 3 Mic1 microphone connect to pre amplifier with 7 pin or 5 pin interface when theMic1 micr...

Страница 9: ...e gain MIC input gain can be controlled in 10 44 dB by adjusting the size Fig 6 5 P T T 1 2 1 3 7 4 52 4 2 GND PRIORITY CHIME LED PWR MIC INPUT 1 3 5 6 7 1 3 6 GAIN MIC 4 GAIN GAIN GAIN MIC 3 MIC 2 MI...

Страница 10: ...1 3 MASTER knob on the panel in conjunction with BASS TREBLE volume adjustment knob to obtain idea hearing effect AUX 1 3 auxiliary input with RCA connectors input machinery and equipment can be conn...

Страница 11: ...ction provides the power amplifier to use as pre amplifier of enlarge signal with the power function expansion Note Output balance XLS line output connect with amplifier input interface must adjust vo...

Страница 12: ...is cut off supply such as line was cut off in the emergency 24V DC power supply electricity to equipments 6 9 2 Power input Fig 6 9 1 Power is to provide energy to equipment must be safe use of power...

Страница 13: ...and floor with screws 3 Then install equipment panel 4 Finally to install cover Transformer Audio PCB Board Power input Panel Power swtich 1 1 4 2 3 POWER TREBLE AUX 1 AUX 2 AUX 3 MIC 1 MIC 2 MIC 3 MI...

Страница 14: ...EC AUX1 AUX2 AUX3 48V PHANTOM MIC2 MIC3 MIC4 MIC5 OFF ON ON OFF ON OFF ON OFF 2 1 3 ON 1 2 3 4 1 2 3 1 2 3 1 2 3 1 2 3 9 CONNECTION DIAGRAM AUDIO OUT R L CD PLAYER LINK INPUTS XLR BAL 1 GND 2 HOT 3 CO...

Страница 15: ...10 BLOCK DIAGRAM AUX 1 3 1 2 4 COMP COMP COMP GAIN AMP GAIN AMP 220V 240V 50 60Hz 13...

Страница 16: ...ms Un AUX 1 2 3 10KOhms 300mVUn EMC 775mV 15KOhms Un balance balance balance balance DIMENSION NET WEIGHT GROSS WEIGHT POWER INPUT T 1S01 3 75Kg 4 75Kg OUTPUT BASS 10dB at 100Hz TREBLE 10dB at 10KHz 2...

Страница 17: ...IC 1 2 1 3 7 4 52 4 2 GND PRIORITY CHIME LED PWR MIC INPUT 1 3 5 6 7 1 3 6 GAIN 5 MIC 5 GAIN 4 GAIN 3 GAIN 2 MIC 4 MIC 3 MIC 2 OUTPUT EMC INPUT REC AUX1 AUX2 AUX3 48V PHANTOM MIC2 MIC3 MIC4 MIC5 OFF O...

Страница 18: ...Version V0 5 PUBLIC ADDRESS SYSTEM...

Отзывы: