![ITC elio VersiColor TPB12RW-LLLWL Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/itc/elio-versicolor-tpb12rw-lllwl/elio-versicolor-tpb12rw-lllwl_install-instructions_2095052002.webp)
3030 Corporate Grove Dr • Hudsonville • MI • 49426
Phone: 616-396-1355 • www.itc-us.com • [email protected] • DOC#: 710-00078 Rev C • 02/14/19
For warranty information please visit www.itc-us.com\warranty
4.
Please review the considerations below to ensure a successful installation.
When bending the wire ensure the bend
point is after the wire clip.
Do not bend right at jacket exit
Do not horizontal bend to a radius of less than 11.8”
R11.8”
Do not bend flexible
light at 90°
Do not bend to a ra-
dius of less than 1/2”
R0.59”
Do not axial bend to the height
of more than 0.312” within 0.78”
segment
0.78”
Less than 0.312”
Do not twist more than 90° over
the length of one 24V segment
/ Two 12V segments (4” total
length)
4”
Axis
*RNLL flexible lighting cannot be field cut. Field cutting the light will void the warranty.
3.
Follow the wiring diagram below to wire the light to your system.
RGBW Flex Light
Green (GND)
Black (L)
DC
AC
White (N)
To AC Power
RGBW
Controller
White (W)
Blue (B)
Green (G)
Red (R)
Red (+)
Black (-)
12-24V - 120-220V
Power Supply
Black (+)
RGBW Flex Light
RGBW
Controller
Black (+)
Blue (B)
Green (G)
Red (R)
12V DC (+)
Black (-)
Incoming
12V DC
Power
Fuse
White (W)