background image

 Be sure to read the instructions in this section carefully before use.
 Make sure  to observe  the instructions in this manual as the conventions of safety symbols and messages
 regarded as very important precautions are included.
 We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message Conventions

Safety  symbols and messages  described  below are used in this manual  to prevent  bodily injury and  property 
damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and
 understand the safety symbols and messages so you are thoroughly aware of the potential safety 

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

When Installing the Unit

   Do not  expose  the unit   to rain or an  environment
   where it may be splashed by  water or other liquids, 
   as doing so may result in fire or electric shock.

   Use the unit only with the voltage   specified  on the
   unit.  Using  a  voltage  higher  than  that  which  is
   specified may result in fire or  electric shock.

   Do not cut, kink, otherwise damage   nor modify the
   power  supply  cord.  In  addition,  avoid  using  the
   power cord in close proximity to heaters,  and never
   place heavy objects -- including the unit   itself -- on 
   the  power  cord,  as  doing so may result  in  fire or  
   electric shock.

 Be sure  to replace  the unit's   terminal  cover  after
 connection  completion.  Because  high  voltage   is
 applied to the speaker terminals, never touch these  
 terminals to avoid electric shock.

 Be  sure  to  ground  to  the  safety   ground  (earth)
 terminal to avoid electric shock. Never   ground to a 
 gas pipe as a catastrophic disaster may result.

 Avoid  installing  or  mounting  the  unit  in  unstable
 locations, such  as   on a rickety  table   or  a slanted
 surface.  Doing  so  may  result  in  the  unit   falling
 down,   causing   personal   injury  and/or  property 
 damage.

When the Unit is in Use

   Should  the  following  irregularity  be  found  during 
   use, immediately switch  off  the  power, disconnect
   the  power  supply   plug  from  the  AC  outlet  and 
   contact  your  nearest  

  dealer. Make no further

   attempt  to operate the unit in this   condition as  this
   may cause fire or electric  shock.
     If  you  detect  smoke  or  a strange  smell coming
     from the unit.
     If water or any metallic object gets into the unit
     If the unit falls, or the unit case breaks
     If the power supply cord is damaged (exposure  of
     the core, disconnection, etc.)
     If it is malfunctioning (no tone sounds.)

   To prevent  a fire or electric  shock, never open  nor
   remove  the  unit  case  as  there  are  high  voltage 
   components  inside  the  unit.  Refer all servicing to
   your nearest  

 dealer.

ITC

ITC 

 Do  not  place  cups,  bowls,   or other containers  of
 liquid  or  metallic  objects on top  of the unit. If  they 
 accidentally spill  into the unit, this may cause  a fire 
 or electric shock.

  Do   not   insert    nor   drop    metallic    objects   or 
  flammable  materials  in  the   ventilation slots  of the
  unit's  cover,  as  this  may  result   in  fire  or electric
  shock.

3

1. SAFETY PRECAUTIONS

Содержание T-6223

Страница 1: ...mend that you keep this manual handyfor future reference OPERATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM T 6223 A ON OFF POWER 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 ALARM ZONES 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 VOLUME 5 0 1 2 3 4 6 7 8 9 10 REST T 6223 A MIXER AMPLIFIER AUDIO MIXER AMPLIFIER ...

Страница 2: ...L DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 5 1 User Operation 8 5 2 8 5 3 8 5 4 Address Tag Setup 8 6 APPLICATIONS 10 7 SPECIFICATIONS 11 8 DIMENSIONAL DIAGRAM 12 OPERATION MP3 alarm music player Rest ...

Страница 3: ...t in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstab...

Страница 4: ...g sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched o...

Страница 5: ...rning 4 30 filed input full automation identify expand to300 The T 6223 A is a public address emergency switch with can provide an ideal public address solution from small to big places such us mosques schools hotels and factories to train stadium and air stations 3 FEATURES 5 2 GENERAL DESCRIPTION ...

Страница 6: ...ER Reset button 2 4 ALARM LAYER Display the working 5 SLAVE 1 30 filed warning indicator 6 VOLUME Volume control 1 4 1 FRONT PANEL 4 6 3 5 ON OFF POWER REST 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 ALARM ZONES 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 VOLUME 5 0 1 2 3 4 6 7 8 9 10 4 NOMENCLATURE AND FUNCTIONS 6 ...

Страница 7: ...atus Indicator When the SD card is running PLAYING green light when no SD card ERRER red light 15 IN 1 30 1 30 field warning singal input 16 220 240V 50 60Hz POWER INPUT 4 2 REAR PANEL 15 16 10 11 COM ADDRESS TAG OUTPUT L L R R SD ERROR IN 1 15 IN 16 30 12 13 14 PLAYING NOMENCLATURE AND FUNCTIONS 7 ...

Страница 8: ...the alarm music to stop playing 1 when the address code is designed to 1 T 6223A is designed to first MP3 music playback 1 300 zone alarm 2 when the address code designed for 2 pm T 6223A is designed to second MP3 players 1 300 area pre alarm music 3 when the address code designed for 3 T 6223Ais designed to third sets MP3 playback signal 1 300 Area undo Music 4 when the address code designed othe...

Страница 9: ...r the alarm T 6223Awill keep in an alarm status after disconnecting the alarm input if want to cancel this status press reset button directly also other machine can send a reset order through the RS422 port to T 6223A B normal closed short circuit triggered mode the method is keep the alarm input port shorting trigger the alarm T 6223Awill discharge the alarm status automatically after alarm short...

Страница 10: ...N CH1 CH10 MUSIC IN CH1 CH10 OUT CH6 CH10 OUT CH1 CH5 ALARM IN ALARM OUT A B B A LINE1 IN LINE2 IN AUDIO OUT MIXER AMPLIFIER MIC2 MIC3 PHANTOM 48V PHANTOM 48V OUTPUT COM 4 16 70V 100V AUX OUT MUTE EMC INPUT LINE 1 LINE 2 OFF ON OFF ON MIC2 MIC3 PHANTOM 48V PHANTOM 48V OUTPUT COM 4 16 70V 100V AUX OUT MUTE EMC INPUT LINE 1 LINE 2 OFF ON OFF ON AUDIO OUT R L COM ADRESS TAG AUDIO SOURCES SPEAKERS 10 ...

Страница 11: ...7 SPECIFICATIONS MODEL EMERGENCY SWITCH T 6223 A DIMENSION mm NET WEIGHT GROSS WEIGHT 484X353X88 POWER CONSUMPTION POWER REQUIREMENTS 220 240V 50 60Hz 6 5Kg 5 3Kg 30W 11 ...

Страница 12: ...3 14 15 1 2 3 4 5 6 7 8 9 10 ALARM ZONES 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 VOLUME 5 0 1 2 3 4 6 7 8 9 10 COM ADDRESS TAG OUTPUT L L R R SD ERROR PLAYING IN 1 15 IN 16 30 ON OFF POWER REST 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 ALARM ZONES 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 VOLUME 5 0 1 2 3 4 6 7 8 9 10 12 ...

Страница 13: ...AUDIO AUDIO PUBLIC ADDRESS SYSTEM VersionV0 1 ...

Отзывы: