Software Configurations
Users will be able to login the system via Console, Telnet, CLI, or Web to execute advanced
configuration using the following username and password.
LAN IP
Configurations
Default IP
192.168.1.1
User Name:
admin
Password:
admin
Via CLI and Telnet
Command: ip set interface iplan
ipaddress <IP>
Via EmWeb
1. From the Configuration menu,
click on LAN connections. The
right image is displayed and
then click on
“
Change default LAN
port IP address”
2. Then type new primary address
detail as follow image showed on the
right.
SHDSL Port
Configurations
Click on Shdsl from the Port
Configuration menu. When Shdsl
Port Configuration page is
displayed, basic port settings are
provided to configure, shown on
the right. Click on “Apply” to
submit your setting or “Cancel” to
clear your setting.
Via EmWeb
Click on Wire Mode drop-down list
to select the Wire Pair number
needed.
Wire Mode
Configuration
Management
Via CLI and Telnet
Command: port shdsl set WirePair < EFM_Bonding / ATM 1-pair / ATM 2-pair /
ATM 3-pair / ATM 4-pair / EFM 1-pair / EFM 2-pair / EFM 3-pair / EFM 4-pair />
CO/CPE Mode
Selection
Via EmWeb
Click on Role drop-down list to set
the device role as CO or CPE
Via CLI and Telnet
Command: port shdsl set UnitID
<StuC/StuR>
Max/Min Line
Rate
Configuration
Via EmWeb
To set the device’s line rate, set
the maximum and minimum line
rate in the Max Line Rate and Min
Line Rate fields respectively
(192000bps to 569000bps)
Via CLI
Command: port shdsl set
<MaxLineRate/ MinLineRate> <value>