9
Figure 12
Install the mounting gasket on the product so that a layer of applied sealant is between the mounting gasket
and the product's base plate.
Apply a layer of sealant with a thickness of not more than 2 mm to the object in the zone bounded by the main
and mounting holes (Fig. 6). Part of the sealant pressed out when mounting the product should not block the
drainage hole of the product.
Use the self-tapping screws supplied with the product to secure the product to the object. The screw with a
sealing hole will be located on the side of the corrugated hose.
4.2.
Cable routing
When mounting, the manufacturer's installation cable included in the package or purchased separately shall be
used.
On the way of the laid cables, there shall be no heated parts of the mechanisms and components of the vehicle
so that the insulation coating of the wires does not melt.
There should be no moving parts of the vehicle's mechanisms on the way of laying the cables.
The minimum allowable bending radius of the FLS corrugated hose (internal) is 40 mm.
4.3.
Connecting to an external device
Connect the product to an external device using one of the connection diagrams (Appendix A) according to a
selected data interface.
The purpose of the FLS connector pins and the color marking of the wires are shown in Fig.13.
The purpose of the cable assembly connector pins as well as the color marking of the wires are shown in
Fig.14
Figure 13
Figure 14