Italkero IF08A2 Скачать руководство пользователя страница 10

10

GENERAL

CONTROL PANEL

1

- GREEN Led On = heater On

1b

- GREEN Led Off = heater Off

- RED Led On = burner flame block

2b 

- RED Led Off = heater released

2c 

- RED Led SLOW flashing = pressure switch don’t switch ON

2d 

- RED Led FAST flashing = locked pressure switch

- MIN / MAX flame intensity knob

- GREEN Led On = Wireless control panel activated

4b 

- GREEN Led Off = Wireless control panel disabled

4c 

- GREEN Led flashing = waiting to recognize the Wireless

4d 

- GREEN Led flashing = Wireless default transmission (about. 2,5 minutes)

4e 

- GREEN Led flashing = Wireless data transmission by the change of any parameter

5

- Wireless On button switch = press and hold 2 seconds, LED 4 starts to blink to recognize the Wireless 
(waiting at MAX 60 seconds) after which it automatically reactivates the manual control

5b

- Wireless Off button switch = press and hold 2 seconds, LED 4 turns off automatically activating the

manual controls

- YELLOW Led  FAST flashing = flame ignition cycle: start

6b 

- YELLOW Led  SLOW flashing = burner ON turned to MIN heating

6c 

- YELLOW Led  On = burner ON turned to MAX heating

6d 

- YELLOW Led  Off = burner off, temperature reached

- Heater On/Off button switch

7b 

- RESET button switch = when switch On again, the Heater restart automatically

1

2

3

4

5

6

7

3

1

2

Check the correct position of the Switches
on the control unit (1) by loosening the

screws (2) and removing the cover (3).

Содержание IF08A2

Страница 1: ......

Страница 2: ...ectromagnetic directive compatible 89 336 CEE Low tension directive 73 23 CEE 0694 RANGE 80 insert IF08A3 M1000 1 side PEBBLES IF08A3 M2000 1 side SMALL WOOD IF08A2 M1000 2 sided PEBBLES IF08A2 M2000...

Страница 3: ...urer 3 GENERAL WARRANTY Our appliances are covered by a SPECIFIC WARRANTY starting on the date of validation by the Authorised After Sales Service of your area whose address you can find on our websit...

Страница 4: ...re 27 Wood wall protection KIT 28 Power connections 29 Gas supply connection 29 TECHNICAL ASSISTANCE Operations to be performed before initial start up 30 First start up 30 Control panel malfunction 3...

Страница 5: ...igned The Manufacturer disclaims any contractual and non contractual liabi lity for injuries caused to people or animals and damage to things due to installation errors wrong settings bad maintenance...

Страница 6: ...ccur outside the installation premises In view of their small size they can be installed in very compact spaces and ensure a greater well being of the heated environment The natural convective movemen...

Страница 7: ...3 14 15 16 17 18 19 21 22 23 26 27 9 23 28 29 14 30 24 19 31 32 33 5 25 33 20 environment probe 21 pressure switch 1 22 control unit 23 gas inlet pipe 24 pressure switch 1 pressure point 25 combustion...

Страница 8: ...IF13A2 C12 C32 C42 C52 DESCRIPTION Code Mod 80 casing with installation in middle of room Mod 80 casing with wall installation short side Mod 80 casing with wall installation long side RH controls Mo...

Страница 9: ...PS2 C52 SAS VC VT CN T1 VT TA BL WH RD SC EA ER EV1 F CL EV2 L N PS TL1 EP SPLIT ROOM PROBE COMBUSTION FAN TANGENTIAL FAN CONNECTOR POWER TERMINAL TANGENTIAL FAN IGNITION TRANSFORMER BLUE WIRE WHITE W...

Страница 10: ...parameter 5 Wireless On button switch press and hold 2 seconds LED 4 starts to blink to recognize the Wireless waiting at MAX 60 seconds after which it automatically reactivates the manual control 5b...

Отзывы: