16
INSTALLER
GENERAL INFORMATION
This appliance is sealed
from the surrounding envi-
ronment in which it is installed and consequently
combustion air is only aspired from outside!
- When installing, NEVER use accessories or com-
ponent parts not approved by the Manufacturer, as
these could be very dangerous.
- DO NOT allow the power cable (if present) to come
into contact with hot surfaces such as, for example,
the air vents or fume exhaust pipes.
After installation, the fitter is obliged to inform the
user what to do during appliance operation:
- NEVER place curtains, towels and the like on the
appliance as this could be the cause of malfunction
and danger and prevent the correct circulation of air
in the room.
- DO NOT obstruct the suction/exhaust ends of the
appliance with washing put out to dry or carpets.
POSITIONING THE APPLIANCE
Installable in any type of premises except garages
and combustible or inflammable material warehou-
ses. The place of installation does not require vents
but must be able to be ventilated with doors or win-
dows communicating with the outside and which can
be opened.
In the case of LPG appliances, these cannot
be installed in premises which have floors
below the outside walk-on surface or communi-
cating with such type of environment.
Before proceeding with the masonry works, make
sure the floor has adequate load-bearing capacity
and that there is room enough for the correct opera-
tion of the gas Appliance as well as its maintenance.
Make sure the wall on which the appliance is faste-
ned is able to support its weight.
Make sure there is no wood matchboard, plastic
material, etc., that is not heat resistant and which
could come into contact with the fume exhaust pipes
(see examples A - B - C - D).
The wall on which the appliance is fastened must be
able to resist the high temperatures of the exhaust
pipes (about 180°C), otherwise an inter-space will be
to be created around the pipe, to be insulated with
materials suitable for the temperatures or a hole will
have to be made having a diameter increased by at
least 4 cm with respect to the pipe.
Installing the Appliance in spare bathroom
areas or close to water dispensers is forbidden.
These particular installations require special protec-
tions in compliance with applicable Electric Safety
standards.
Gas supply
The correct operation of the appliance also depends
on the size of the pipes.
Comply with the standards in force in the
country where the device is installed.
INSTALLATION
A
B
C
D
Содержание Camino Series
Страница 1: ...South Africa...
Страница 7: ...7 GENERAL TECHNICAL DATA 150 200 150 150 150 200 3...
Страница 8: ...8 GENERAL ACCESSORIES...
Страница 12: ...12 INSTALLER DIMENSION mod 70 2 sided 1 side mod 50q 2 sided 1 side...
Страница 13: ...INSTALLER 13 mod 90 2 sided 1 side mod 130 2 sided 1 side...
Страница 14: ...INSTALLER 14 min 245 max 495 307 mod 130F 3 sided wall mod 130P 3 sided peninsula...
Страница 32: ...35200218 Rev 15...