background image

 

 

 

C

 

 The indicator light provides the status of the Active Probe as follows: 

o

 

Permanently green  - Powered On and ready to use 

o

 

Blinking green 

 Establishing connection with the BlueBox 

o

 

Blinking blue 

 Reprogramming SPLASH 

o

 

Permanently magenta 

 Golden image loaded and ready to use 

 

D

 

 FNet connector, that connects the Active Probe to the iC5700 BlueBox. The FNet cable is 

delivered with the Active Probe. 

 

When powering  on the  system,  switch  the  iC5700  on  prior  to  powering  on the  target 
system; when powering down the system, power off the target microcontroller before 
powering off the iC5700. 
Use only original iSYSTEM accessories for powering and connecting with the iC5700.  
Consult with iSYSTEM before attempting to use any other accessory. 

 

Target connector  

The  target  should  feature  a  matching  part,  for  example,  Samtec  part  number:  ASP-137969-01 
(Samtec Series ERF8, Rugged High-Speed Socket). 
 
Infineon  TriCore  target  can  also  feature  a  standard  10-pin  1.27mm  DAP  target  debug  connector 
exposing  only  the  debug  interface  without  the  AGBT  interface.  The  Active  Probe  can  be  used  to 
connect  to  such  targets  through  a  small  adapter  connecting  at  the  end  of  Samtec  22-pin  ERF8 
connector. 

 

10-pin 1.27 mm DAP Adapter 

 

 

 

 
 
 
 
 
The 10-pin connector must be ordered separately in order to connect to the target featuring 10-pin 
1.27mm pitch DAP target debug connector. 

 

The following pinout is valid on the target side: 

Signal direction 

Signal 

Pin  Pin 

Signal 

Signal direction 

VREF 

DAP1 

O / IO 

Ground 

GND 

DAP0 

O / O 

Ground 

GND 

DAP2 

 

Not Connected 

DAP_EN 

Ground 

GND 

10 

~PORST 

IO 

10-pin 1.27mm TriCore DAP pinout 

 
 

Ordering code  IASAM22TRICOREP10-1 

Содержание IC57164

Страница 1: ...Infineon AGBT Active Probe V1 7 User Manual ...

Страница 2: ...ghts are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required Copyright iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Страница 3: ...n 8 Device overview 8 Device description 8 Target connector 9 10 pin 1 27 mm DAP Adapter 9 Active Probe and the iC5700 Connecting Guidelines 11 Setting Debug Interface Voltage Levels 11 Further Active Probe Settings 12 Lane link speed 14 Accessories 15 Infineon AGBT Active Probe Accessories 15 ...

Страница 4: ...winIDEA can also visualize the timing and code coverage of the application via the trace interface as well as combine data captured by our IOM Accessories Various third parties also provide software tools to perform advanced worst time execution analysis based upon the data winIDEA can export When a Real Time Operating System RTOS is in use the state of the RTOS and its tasks can also be visualize...

Страница 5: ...s is to avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not to...

Страница 6: ...s InfineonAGBTActiveProbe 1 m FNET Cable User manual Ordering code IC57164 Ordering code BB FNET 100 The Infineon AGBT Active Probe kit ordering code IC57164 62 can be delivered with longer cable i e 62 cm in length InfineonAGBTActiveProbe 1 m FNET Cable User manual Ordering code IC57164 62 Ordering code BB FNET 100 ...

Страница 7: ...ox iSYSTEM proprietary FNet Debug signal valid input voltage range 3 3V max 3 6V Power consumption Max 3W dependent on operation mode Number of supported AGBT lanes Up to 4 Maximum AGBT bitrate 5Gbps AGBT clock source options Active Probe PROTECTION Debug signals 33Ω series termination protection resistors ESD protection devices DAP1 3 10kΩ pull down DAP_RESET 1kΩ pull up 33Ω series termination pr...

Страница 8: ...1 12 TRST DAPEN Output O I AGBT TX2_P TX2 13 14 CLK AGBT clock O I AGBT TX2_N TX2 15 16 CLK AGBT clock O Ground GND 17 18 TGO AGBT trigger out I AGBT TX3_P TX3 19 20 NC Not Connected I AGBT TX3_N TX3 21 22 RESET Target Reset Pin IO Current TriCore devices feature only one AGBT lane while the Active Probe hardware is ready for future devices which could have more AGBT lanes Signal direction definit...

Страница 9: ...any other accessory Target connector The target should feature a matching part for example Samtec part number ASP 137969 01 Samtec Series ERF8 Rugged High Speed Socket Infineon TriCore target can also feature a standard 10 pin 1 27mm DAP target debug connector exposing only the debug interface without the AGBT interface The Active Probe can be used to connect to such targets through a small adapte...

Страница 10: ...10 If the 10 pin 1 27 mm pitch ribbon cable gets damaged it can be ordered as a spare part under the ordering code IA10PIN10PIN127 Detached 10 pin 1 27mm pitch ribbon cable ...

Страница 11: ... Connect the iC5700 to the PC via the supplied Ethernet or the USB 3 0 cable Connect the Active Probe to the iC5700 FNET Port through the supplied FNET Cable If a cable longer than 1 0m is required for example when debugging an ECU in a vehicle or a confined space optional 3m and 5m FNET cables are available from iSYSTEM Although it looks similar to the HDMI interface the FNET Port is not compatib...

Страница 12: ...atively JTAG debug interface support is also available through a dedicated JTAG cable adapter e g IC50160 or the Infineon DAP Active Probe supporting the DAP and DAPE debug interface or the Infineon AGBT Active Probe In order to switch from the default DTM interface use to the Active Probe use open Hardware menu Options FNet tab 1 In Currently connected FNodes section click Refresh and select the ...

Страница 13: ...d select the displayed AP Infineon AGBT If you have several Active Probes connected to your BlueBox select the desired Active Probe from the drop down menu If you have only one Active Probe connected you can leave the Active Probe selection box empty and winIDEA will automatically connect to an available Active Probe ...

Страница 14: ... interface Hence once the Analyzer trace operation e g trace or profiler or coverage is confirmed with the default setting higher Aurora link speeds should be tested and the highest operational speed then selected for usage This way the Active Probe will be configured for maximum possible Analyzer session time Different speeds 1 25Gbps 2 5Gbps are available Other more general of Infineon s AURIX m...

Страница 15: ...41 Analog Digital Input Output Add On Module IC57125 1 ARM HSSTP II Active Probe IC57163 Infineon DAP DAPE Active Probe IC57164 Infineon AGBT Active Probe IC57150 MPC5x SPC5x Aurora Active Probe Infineon AGBT Active Probe Accessories Ordering Code Description IASAM22TRICOREPIN10 10 pin 1 27 mm DAP Adapter BB FNET 100 1 0m FNet Cable BB FNET 300 3 0m FNet Cable BB FNET 500 5 0m FNet Cable Please re...

Страница 16: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...

Отзывы: