Important safety notice

General safety instructions 

Please read the  following  safety  precautions  carefully  before  putting

this device  to  use  to  avoid  any  personal  injuries,  damage  to  the  instrument,  or  to  the  target  system.
Use  this  instrument  only  for  its  intended  purpose  as  specified  by  this  manual  to  prevent  potential
hazards.

Use included power cord and power supply 

The  enclosed  power  supply  has  been  approved  for

use by iSYSTEM. Please contact iSYSTEM if you need to consider an alternative power.

Use grounding wire

 - 

Prior to applying power to either the  BlueBox  or  the  target,  connect  the  device

and  the  target  system  together  with  the  included  grounding  wire.  This  is  to  avoid  potential  damage
caused by any voltage difference between the device and the target system.

Use  proper  overvoltage  protection 

Please  ensure  proper  protection  to  avoid  exposing  the

BlueBox device or the operator to overvoltage surges (e.g. caused by thunderstorm, mains power).

Do not operate without cover

 - 

Do not operate the device with cover removed.

Avoid circuit and wire  exposure

  - 

Do  not  touch  exposed  components  or  wires  when  the  device  is

powered.

Do not operate with suspected damage

 - 

If you suspect damage may have  occurred,  the  BlueBox

device must be inspected by qualified service personnel before further operation.

Do not operate the device outside its rated supply voltage or environmental range

 - 

Consult

with iSYSTEM before using equipment outside of the parameters provided in this manual.

This symbol is used within the manual to highlight further safety notices. 

Содержание IC50000-CI

Страница 1: ...iC5000 CI BlueBox User Manual V1 3 ...

Страница 2: ...d by iSYSTEM AG and all rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All trademarks are property of their respective owners www isystem com ...

Страница 3: ...tents iC5000 CI BlueBox Important safety notice 5 Package content 6 Specifications 7 Operation 8 Device description 9 Connecting the iC5000 CI to the Target 11 Accessories 14 Declarations 16 User Notes 17 ...

Страница 4: ...velopment Environment delivers the visual insights required to debug the embedded application performs timing analysis measures code coverage visualizes RTOS task states and much more More information isystem com winideaide testIDEA The testIDEA environment simplifies the development of unit tests for embedded applications More information isystem com testidea isystem connect Application programmi...

Страница 5: ...o avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not touch ex...

Страница 6: ... iC5000 CI with pre assembled DTM module 25 cm 40 pin ribbon cable Power supply Ordering code IC50000 CI Ordering code IC50020 25 Ordering code IC30000 PS USB 2 0 cable Ethernet cable Grounding wire Ordering code BB USB20 180 Ordering code BB ETHCAT5 200 Ordering code BB WIRE User Manual ...

Страница 7: ...ltage range 1 8V to 5 5V DC Debug signals 47 series termination protection resistors ESD protection devices Depending on the specific debug adapter termination might be different from 47 on some critical signals All inputs except the TDO 10 kOhm pull up resistor TDO input 10 kOhm pull down resistor TMS and TDI debug signals 10 kOhm pull up resistor RESET 1 kOhm pull up resistor buffer driven to pr...

Страница 8: ...Operation Device overview ...

Страница 9: ...Indicator On BlueBox is available for a connection from a host PC Off Active connection to the BlueBox from a host PC exists The front face of the iC5000 CI features C The grounding socket marked GND should be used together with the supplied Grounding wire to create an electrical connection between the BlueBox and the target circuitry The socket is suitable for a 2 mm Multi Contact Plug also known...

Страница 10: ...nected to a network PC simultaneously The active interface will be determined by whichever interface winIDEA connects to first When powering on the system switch the BlueBox unit on before powering on the Target When powering down the system power off the Target before powering off the BlueBox unit FBridge port is not Ethernet port Use only original iSYSTEM accessories for powering and connecting ...

Страница 11: ...age range from 10V to 24V DC thus enabling the BlueBox hardware to work also with a 12V or 24V vehicle battery The necessary power supply Part No IC30000 PS is delivered with the BlueBox The power supply comes with the EU type F power plug USA type B power plug India type D power plug or China type I power plug power cord depending on the delivery address Refer to the Accessories chapter for a spa...

Страница 12: ...in and one 40 pin with a permanently fitted to the debug adapter 1 Connect the 40 pin ribbon cable connector to the DTM 1 socket The ribbon cable must always be guided towards the BlueBox front panel with the red wire on the side of the 1 marking optional 2 Align the orientation key of the cable connector with the notch on the BlueBox s 40 pin socket the wider of the two sockets Carefully press th...

Страница 13: ...nect the ribbon cable squeeze the two metal latches on the cable connector inwards and pull the connector gently from the socket If the delivered ribbon cable does not meet your needs iSYSTEM offers a range of alternative lengths Please refer to the Accessories chapter for available ribbon cables The quality of electrical signals degrades with prolonging the cable iSYSTEM gives no assurance for Bl...

Страница 14: ...ly Cord India Plug type D Plug BB PSC CN Power Supply Cord China Plug type I Plug IC50020 10 10 cm 40 pin Ribbon Cable IC50020 25 25 cm 40 pin Ribbon Cable IC50020 40 40 cm 40 pin Ribbon Cable IC50020 60 60 cm 40 pin Ribbon Cable IC50020 100 100 cm 40 pin Ribbon Cable IC50020 150 150 cm 40 pin Ribbon Cable BB USB20 180 1 8 m USB 2 0 Cable BB USB30 180 1 8 m USB 3 0 Cable BB USB30 A10M 10 m Active ...

Страница 15: ...ug Adapter IC50152 38 pin Mictor MPC5xxx Nexus 16 bit Debug Adapter IC50152 12 38 pin Mictor MPC5xxx Nexus 16 bit Debug Adapter IC50156 50 pin ERF8 MPC5xxx Nexus 16 bit Debug Adapter IC50160 16 pin 2 54mm Infineon JTAG Debug Adapter IC50160 ECU14 10 pin 1 27mm TriCore ECU14 Debug Adapter IC50160 MEDC17 10 pin 1 27mm TriCore MEDC17 Debug Adapter IC50162 6 pin 2 54mm Infineon I2C Debug Adapter IC501...

Страница 16: ...evice The object of declaration described above is in conformity with the relevant Union harmonization legislation EMC directive 2014 30 EU and RoHS directive 2011 65 EU The following harmonized standards and technical specifications have been applied to EN 55032 2012 EN 55024 2010 EN 61000 3 2 2014 EN 61000 3 3 2013 Signed for and on behalf of Schwabhausen 21 March 2017 iSYSTEM AG f Informatiksys...

Страница 17: ...User Notes This page is intentionally left blank ...

Страница 18: ...This page is intentionally left blank ...

Страница 19: ...This page is intentionally left blank ...

Страница 20: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...

Отзывы: