background image

Connecting the iC5000 CI to the Target

Grounding wire

Always  start  by  connecting  the  BlueBox  to  the  Target  with  the  Grounding  wire.  Refer  to

www.isystem.com/groundingwire

 for more information. 

If  the  Grounding  wire  is  not  connected,  the  ground  potential  difference  between  the
BlueBox hardware and the Target can exceed well  over  1000V  even  before  any  of  the
devices  are  powered  up.  This  voltage  difference  is  discharged  over  the  BlueBox
hardware and the Target, leading to the possible destruction of electronic components
within the BlueBox hardware, the Target or both.

Power Supply

The BlueBox unit accepts a wide input voltage range from 10V to 24V DC, thus  enabling  the
BlueBox hardware to work also with a 12V or 24V vehicle battery. The necessary power supply
(Part No. IC30000-PS) is delivered with the BlueBox unit. The power supply comes with the EU
(type F power plug), USA (type B power plug), India (type D power plug) or China (type I power
plug) power cord  depending  on  the  delivery  address.  Refer  to  the  Accessories  chapter  for  a
spare power cord when required.

An optional 12V power supply adapter suitable for use in a vehicle can be ordered using  the
ordering code IC30000-PS-CAR12V.

When  powering  on  the  system,  switch  the  BlueBox  unit  on 

before

  powering  on  the

Target. When powering down the system, power off the target before powering off the
BlueBox unit!
FBridge port is not Ethernet port!
Use 

only original

 iSYSTEM accessories for powering and connecting with  the  BlueBox

unit. Consult with iSYSTEM before attempting to use any other accessory.

Содержание iC5000 CI BlueBox On-Chip

Страница 1: ...iC5000 CI BlueBox On Chip Analyzer User Manual V1 1 ...

Страница 2: ...ll rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Страница 3: ...I BlueBox Important safety notice 5 Package content 6 Specifications 7 Operation 8 Device description 9 Connecting the iC5000 CI to the Target 11 Accessories 14 Declarations 16 User Notes 17 User Notes 18 User Notes 19 ...

Страница 4: ...Environment delivers the visual insights required to debug the embedded application performs timing analysis measures code coverage visualizes RTOS task states and much more More information isystem com winideaide testIDEA The testIDEA environment simplifies the development of unit tests for embedded applications More information isystem com testidea isystem connect Application programming interfa...

Страница 5: ...o avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not touch ex...

Страница 6: ...iC5000 CI with pre assembled DTM module 25 cm 40 pin ribbon cable Power supply Ordering code IC50000 CI Ordering code IC50020 25 Ordering code IC30000 PS USB 2 0 cable Ethernet cable Grounding wire Ordering code BB USB20 180 Ordering code BB ETHCAT5 200 Ordering code BB WIRE User Manual ...

Страница 7: ...ltage range 1 8V to 5 5V DC Debug signals 47 series termination protection resistors ESD protection devices Depending on the specific debug adapter termination might be different from 47 on some critical signals All inputs except the TDO 10 kOhm pull up resistor TDO input 10 kOhm pull down resistor TMS and TDI debug signals 10 kOhm pull up resistor RESET 1 kOhm pull up resistor buffer driven to pr...

Страница 8: ...Operation Device overview ...

Страница 9: ...controller is halted F Free Indicator Yellow On BlueBox is available for a connection from a host PC Off Active connection to the BlueBox from a host PC exists The front face of the iC5000 CI features C The grounding socket marked GND should be used together with the supplied Grounding Wire to create an electrical connection between the iC5000 and the target circuitry The socket is suitable for a ...

Страница 10: ...2 0 Socket can be connected to a network PC simultaneously The active interface will be determined by whichever interface winIDEA connects to first When powering on the system switch the BlueBox unit on before powering on the Target When powering down the system power off the Target before powering off the BlueBox unit FBridge port is not Ethernet port Use only original iSYSTEM accessories for pow...

Страница 11: ...BlueBox hardware to work also with a 12V or 24V vehicle battery The necessary power supply Part No IC30000 PS is delivered with the BlueBox unit The power supply comes with the EU type F power plug USA type B power plug India type D power plug or China type I power plug power cord depending on the delivery address Refer to the Accessories chapter for a spare power cord when required An optional 12...

Страница 12: ...in and one 40 pin with a permanently fitted to the debug adapter 1 Connect the 40 pin ribbon cable connector to the DTM 1 socket The ribbon cable must always be guided towards the BlueBox front panel with the red wire on the side of the 1 marking optional 2 Align the orientation key of the cable connector with the notch on the BlueBox s 40 pin socket the wider of the two sockets Carefully press th...

Страница 13: ... ribbon cable squeeze the two metal latches on the cable connector inwards and pull the connector gently from the socket If the delivered ribbon cable does not meet your needs iSYSTEM offers a range of alternative lengths Please refer to the Accessories chapter for available ribbon cables Note that the quality of electrical signals degrades with prolonging the cable iSYSTEM gives no assurance for ...

Страница 14: ...Plug BB PSC IN Power Supply Cord India Plug type D Plug BB PSC CN Power Supply Cord China Plug type I Plug IC50020 10 10 cm 40 pin Ribbon Cable IC50020 25 25 cm 40 pin Ribbon Cable IC50020 40 40 cm 40 pin Ribbon Cable IC50020 60 60 cm 40 pin Ribbon Cable IC50020 100 100 cm 40 pin Ribbon Cable IC50020 150 150 cm 40 pin Ribbon Cable BB USB20 180 1 8 m USB 2 0 Cable BB USB30 180 1 8 m USB 3 0 Cable B...

Страница 15: ...50152 12 38 pin Mictor MPC5xxx Nexus 16 bit Debug Adapter IC50156 50 pin ERF8 MPC5xxx Nexus 16 bit Debug Adapter IC50160 16 pin 2 54mm Infineon JTAG Debug Adapter IC50160 ECU14 10 pin 1 27mm TriCore ECU14 Debug Adapter IC50160 MEDC17 10 pin 1 27mm TriCore MEDC17 Debug Adapter IC50162 6 pin 2 54mm Infineon I2C Debug Adapter IC50163 2 10 pin 1 27mm Infineon DAP2 Wide Debug Adapter IC50164 22 pin ERF...

Страница 16: ...evice The object of declaration described above is in conformity with the relevant Union harmonization legislation EMC directive 2014 30 EU and RoHS directive 2011 65 EU The following harmonized standards and technical specifications have been applied to EN 55032 2012 EN 55024 2010 EN 61000 3 2 2014 EN 61000 3 3 2013 Signed for and on behalf of Schwabhausen 21 March 2017 iSYSTEM AG f Informatiksys...

Страница 17: ...User Notes This page is intentionally left blank ...

Страница 18: ...User Notes This page is intentionally left blank ...

Страница 19: ...User Notes This page is intentionally left blank ...

Страница 20: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...

Отзывы: