Ispring UVF55FS Скачать руководство пользователя страница 5

Installation 

Before Installation 

o

 

The unit comes with two ports. Both are 1-inch MNPT and can be used as an inlet or outlet. Please choose the correct 

fittings to fit your plumbing. For easy maintenance, it is recommended that you install an inlet valve and an outlet 

valve before and after the unit. Please make sure that it can be easily disassembled from the water line for future 

maintenance. 

o

 

The unit should be installed after a sediment filter, as sediments in the water can block UV light and become a shelter 

for contaminants. Thus, water coming into the UV filter must be clear (free of particles larger than 20 microns). It is 

recommended that you install the UV filter after the filters as the last stage. 

o

 

If water flow speed exceeds rated flow, please install a flow-limiting or pressure-limiting device. If the water pressure 

is over 43 psi, please install a pressure regulator in the inlet/outlet in order to protect the quartz sleeve. 

o

 

Please install the filter at a position by the retaining clip, retaining nuts or other mounting device in order to prevent it 

from dropping due to the vibration caused by water and causing damages to the internal fragile parts. 

o

 

The ultraviolet water filter is not designed  to eliminate bad tastes or smells, biological materials, chemicals, silt, heavy 

metal and other kinds of impurities, and it does not reduce sediments which affects the efficiency of the UV lamp. 

Therefore, it is necessary to install a pre-filter to ensure that the filter can achieve optimal performance. 

Installation Steps 

Step1 

- Before mounting the two black plastic clips onto the wall, make sure there is enough room for both the stainless-steel 

housing and access for future servicing. It can be installed horizontally or vertically. (If you choose vertical mounting, make sure 

that water inlet ismounted at a lower level while the outlet is at a higher level to slow down water flow and increase exposure 

to the UV light. 

- 4 - 

 

Содержание UVF55FS

Страница 1: ...iSpring Whole House Ultraviolet Light Water Filter Installation and Maintenance Manual Model UVF55FS Please read the User s Manual Carefully and keep it available...

Страница 2: ...s so that you know you and your loved ones get clean and worry free water for drinking washing showers and more Build your trust in water for your entire household by removing risks unable to be addre...

Страница 3: ...U POE Point of Entry Input 110 120V 50 60Hz UV Bulb Model UVB55FS 1 Filter chamber 304SS 2 Clamps 3 Nut 4 Flow switch 5 Quartz tube 6 O rings 7 UV lamp 8 Open end nut 9 Cover Cap 10 UV lamp socket 11...

Страница 4: ...ing bumping freezing overheating and corrosive chemicals Specs and Conditions Operating Parameters Maximum Operating Pressure 85psi Minimum Operating Pressure 4psi Maximum Ambient Air Temperature 100...

Страница 5: ...ssure regulator in the inlet outlet in order to protect the quartz sleeve o Please install the filter at a position by the retaining clip retaining nuts or other mounting device in order to prevent it...

Страница 6: ...switch Make sure that the Quartz Tube and UV Lamp are clean before installation clean it with alcohol or mild detergent Wear soft non abrasive gloves to keep any finger marks away from them Step3 Rem...

Страница 7: ...o the closed end of the quartz tube Step7 Hand screw closed end nut on the filter chamber closed end of quartz tube To protect the O ring do not over tighten Step8 Hand screw open end nut on the filte...

Страница 8: ...rtz tube through open end nut Step 9 Connect 4 pin electrical socket with UV lamp pins tightly Step 11 Install the cover cap and hand tighten onto open End Nut Step 12 Insert the flow switch on the ou...

Страница 9: ...control switch to button AUTO the UV lamp will starts working automatically when there only water flowing Push control switch to button MOVE the UV lamp keep working continuedly Push control switch bu...

Страница 10: ...Ultraviolet radiation and service life E If this unit falls into the water turn mainpower off and then retrieve it Do not attempt to use this filter if it has been submerged F Do not operate this unit...

Страница 11: ...ly clean the lamp and quartz sleeve at least 2 3 times a year if the unit can be unmounted easily Otherwise please replace the lamp and quartz sleeve every 1 2 years To clean the lamp Wear rubber late...

Страница 12: ...t of UV light created by the lamp decreases over time therefore the lamp should be replaced every 12 months Troubleshooting Symptom Solution Leaking from the UV filter steel pipe nuts The O ring insid...

Страница 13: ...than 85 PSI 3 The system is to be used on water supplies with chlorine concentrations of 1 0 mg L ppm or less 4 Feed water temperature to the unit must be no less than 32 F and no more than 100 F 5 Ma...

Страница 14: ...system If you choose to keep it you understand this exclusion WILL STILL apply to you Owner s Warranty Responsibilities As a condition of this Limited Warranty the owner must ensure that periodic mai...

Страница 15: ...n that information upon registration of your system If you have any questions or concerns about your product please do not hesitate to call or email us You may always insert notes comments upon your w...

Страница 16: ...iSpring Water Systems LLC Atlanta Georgia USA 15...

Отзывы: