Page 14 

disconnected. Open the Feed Water Adapter Valve (AFW43) and Cold Water Supply Valve 
(CWSV), and flush the first three stages into a bucket until the water turns clear.  

8.3

 

Once the water is clear, shut off the AFW43 and reconnect the tubing to the RO membrane 
housing cap. You will want to flush the first three stages like this whenever they are 
changed. 

8.4

 

Open the RO faucet. Slowly open the AFW43 back up and 

check for any leaks. The top 3 

causes of leaks are 1) The tubing is not fully inserted into the quick-connect fitting. 2) 
The O-ring is not in the correct place or is kinked. 3) The Housing/Cap is not 
tightened properly or is misaligned with the threads. 

 

8.5

 

Within 5 minutes, the booster pump will kick on and RO water will start slowly trickling 
from the faucet. Let the faucet trickle for at least 15 minutes to flush out the entire system 
apart from the tank. The water may appear black at first due to loose carbon from new 
carbon filters. It will eventually turn clear apart from many tiny air bubbles leaving the 
system.  

8.6

 

Shut off the RO Drinking Faucet. Open the Tank Shut-off Valve. Wait for the tank to fill up 
completely. It will take 1 to 2 hours depending on your water temperature (40F-100F, the 
warmer the faster) and source water TDS (up to 750 ppm, the lower the faster). The pump 
will shut off automatically when the tank is full. 

8.7

 

After the tank is full, open the RO Drinking Faucet to drain the tank completely. Do not use 
the first tank of water. Let it drain into the sink until the stream turns back to a trickle. This 
means the tank has emptied and you can close the RO faucet to let it begin filling again.  

8.8

 

*

 If your system has a UV filter, plug in the UV power and check to make sure the UV light 

is turning on when water flows through it. The UV filter has a Flow Sensor Switch that 
detects water flow and only turns the light on when needed. If the UV is not turning on 
when water flows through, confirm the power source you are using has power. Typically, 
the garbage disposal outlet only has power when the disposal is switched on.  

8.9

 

The TDS (total dissolved solids) of the water should be tested periodically to verify that the 
system is performing properly. iSpring RO systems have earned 

WQA GOLD SEAL

 by 

exceeding the minimum requirements for NSF/ANSI standard 58 and should be giving an 
average TDS reduction rate of 90%+, so if your tap water is 100ppm you should be getting 
10ppm or less from the RO water (200/20>, 400/40> etc.). This reverse osmosis system 
contains a replaceable treatment component, critical for the effective reduction of total 
dissolved solids and that product water should be tested periodically. TDS is measured with 
a TDS meter - it is an inexpensive, easy to use device that can be found on Amazon.com or 
123filter.com by searching “iSpring TDS”.  

     8.10 Check for leaks daily for the first two weeks after installation to ensure the system is       
             functioning properly. Install the included Flood Alarm to provide additional peace of mind  
             and protection. 

 
Note:

 Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before or after the system. Systems certified for cyst reduction may be used 
on disinfected water that may contain filterable cysts. 
 

Congratulations, you have successfully installed your

 

iSpring Reverse Osmosis Water Filtration System!

 

 

Start enjoying fantastic reverse osmosis water right from your tap!

 

 

-------------------------------------

End of Installation Section

------------------------------------ 

 

Содержание RCC1P

Страница 1: ...iSpring Reverse Osmosis Water Filtration Systems INSTALLATION INSTRUCTIONS OWNER S MANUAL Ver 02 2020 Copyright 2005 2020 ISPRING WATER SYSTEMS LLC All rights reserved...

Страница 2: ...m has certified by WQA to NSF ANSI Standard 58 for the reduction of TDS as verified and substantiated by test data Please review the attached iSpring RO System WQA Gold Seal Certification or the WQA w...

Страница 3: ...alling the RO Faucet 9 Step 3 Installing the Drain Saddle 9 Step 4 Installing the Vertical Filters Stages 1 2 and 3 10 Step 5 Installing theTank Shut Off Valve 10 Step 6 Installing the Reverse Osmosis...

Страница 4: ...r pressure 70 PSI otherwise a pressure regulator part no APR70 is required to lower the PSI to the maximum level Operating water temperature range 40 100 F 4 37 C This RO system is NOT designed for HO...

Страница 5: ...in moisture 3 Pre Filter Housings and Cartridges Storage Tank RO faucet with installation kit Feed Water Adapter AFW43 4 Color Tubing Set Drain Saddle Tank Valve Housing Wrenches Plumbers Tape Spare O...

Страница 6: ...ort and waste water port The RO water is forced through the 0001 micron sized holes of the RO membrane and exits through the one way Check Valve on the membrane s pure water exit port The water reject...

Страница 7: ...k sleeve pops out of the fitting when doing this simply pop it back in 4 Insert the tube into the fitting until you reach the mark on the tube You will feel resistance when the tube reaches the small...

Страница 8: ...in your sink or counter top 1 It s highly recommended to watch the YouTube video How To Drill Faucet Holes to get a better understanding of the process Depending on what kind of countertop you have yo...

Страница 9: ...e pure water line and the flow restrictor doubles as one way valve preventing drain water from entering back into the system Installation Steps Before you begin the installation it is highly recommend...

Страница 10: ...ular OFF position Turn on the CWSV slowly and ensure you are getting a proper seal 1 4 Connect the 1 4 RED tubing to the AFW43 Feed Water Adapter with Bushing to convert 3 8 COMP to NPT Step 2 Install...

Страница 11: ...ound the hole 3 3 Cut the BLACK tubing end to make a 45 degree angle Slip the plastic nut and front plate on the tubing Insert the tubing into the 1 4 hole in the drain pipe install the back plate and...

Страница 12: ...go in a certain direction Make sure the end with the rubber washer faces up thereby attaching it to the housing cap Step 5 Installing Tank Shut Off Valve TSV 5 1 Wrap 10 15 wraps of Teflon tape clock...

Страница 13: ...and 9 This is very important to avoid leaking and damage to the O ring 6 6 Place the membrane housing cap back on and hand tighten it then use the housing wrench to tighten it another of a turn Do no...

Страница 14: ...efer to How to Use the Compression Fitting 7 7 You may neatly organize the tubing but make sure to leave enough length so the filter system can be moved freely in and out of the cabinet when replacing...

Страница 15: ...RO faucet to let it begin filling again 8 8 If your system has a UV filter plug in the UV power and check to make sure the UV light is turning on when water flows through it The UV filter has a Flow...

Страница 16: ...epot com This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specificatio...

Страница 17: ...lter housing off without removing the system from the wall Otherwise you will need to pull the system out lay it down and remove the housings at that point Be careful with the tubing connections when...

Страница 18: ...ring is properly seated on the end of the membrane housing as shown in the previous images We recommend replacing the O ring every 3 years to prevent leaking due to an expired or dried out O ring 8 P...

Страница 19: ...Kit ICEK The Ice Maker Kit model iSpring ICEK can be purchased separately to feed RO water to your refrigerator for crystal clear ice cubes and great tasting water If you choose to hook up the system...

Страница 20: ...herefore not allowing water to pass through See Pump does not start b Incorrect installation Verify all tubing connections c Tank valve is closed Make sure the tank valve is in line with the yellow tu...

Страница 21: ...tinuous drain a Keep in mind that it will take anywhere from 1 3 hours for the system to fill the tank from empty and the drain line will be trickling during this time If the drain line continues to r...

Страница 22: ...in line with your cold water line and branches off a water supply line to the RO system Can adapt to and cold water lines Feed Water Solenoid Valve ASOW7 Opens the water supply to the booster pump wh...

Страница 23: ...ir respective caps Stage 1 See Through Sediment Filter Housing HC12 Transparent stage 1 housing that holds the sediment filter The see through housing allows for the sediment filter to be visually ins...

Страница 24: ...nation of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied...

Страница 25: ...ufacturer warranty and lifetime tech support for all of our products However we do not have the order information from websites other than 123Filter com Amazon Home Depot etc so please be sure to fill...

Страница 26: ......

Страница 27: ...3020 Trotters Parkway Alpharetta GA 30004 USA 123Filter com For questions comments or technical support please contact us at support 123filter com 678 261 7611 Monday Friday 8 30 a m 5 30 p m EST...

Отзывы: