background image

Open the COLD-water faucet and run water for about 10 minutes to expel any carbon 
fines. Let the unit sit for several minutes, then repeat if necessary. 

6.

 

Turn off the faucet, and your system is now ready for use. 

 

 

NOTICE:

 

The water will have a blackish color for the initial flush. This is caused by residual carbon dust 

and is to be expected. Continue to run water until the color runs clear and all air has been 

purged. It is not unusual for the water to appear "cloudy" for a day or so following installation. 

This cloudiness is actually tiny air bubbles being purged from the filters. This is normal and will 

cease after a few days of operation. 

 

 

 

 

NOTICE: 

After prolonged periods of nonuse (such as a vacation), it is recommended that the system be 

flushed thoroughly for at least 10 minutes prior to use.

 

Filter Change Instructions 

 

Step 1- Remove Old Cartridges 

 

 

1.1  Turn off the water supply to the system. Open a nearby faucet to release the 

remaining pressure and drain the water. 

 

1.2  Unscrew the housings using the filter wrench included (AWR3) with your system, or 

a commercially available “strap” type wrench.  

 

1.3  Locate and remove the large O-ring using a small, clean flat head screwdriver. Avoid 

removing any of the lubricant, and set it aside in a clean, safe place.  

 

1.4  Remove and discard the old filter cartridges.  

 

 

 

Step 2- Clean the Housings 

 

 

 

2.1  Scrub the housings and caps with a mixture of warm water and about 2 tablespoons 

of household bleach using a sponge or soft rag. For your safety, wear rubber gloves. 

Rinse all parts very thoroughly!

 

 

 

 

2.2  Lubricate the O-ring with clean silicone grease if needed. DO NOT USE PETROLEUM 

JELLY. Insert the O-ring into the filter groove and press into place

Verify the O-ring is 

seated correctly.  

Отзывы: