background image

 

 
 
 
 
 
 

 

IMPORTANT SAFETY INSTRUCTIONS!

 

Please read this very carefully before operating this unit 

 

  Read 

ALL

 instructions carefully before using this unit. 

 

  Do not operate this unit near water, in the rain or where there is moisture.  

If this warning is ignored a serious electrical shock or death may occur. 

 

  Do not attempt to service this unit.  No user serviceable parts inside.  Refer 

servicing to qualified, ISP approved service personnel. 

 

  Never  remove  or  defeat  the  ground  connection  on  the  power  cord  of  this 

unit. 

 

  Care should be taken to avoid spilling any foreign objects or liquid into this 

unit. 

 

  This active speaker system has an internal amplifier and a heatsink located 

inside the back of the cabinet with an internal fan for cooling of the internal 
amplifier.    Care  should  be  taken  to  avoid  placing  this  active  speaker  in  a 
location where the fan in blocked and does not allow proper cooling of the 
internal  amplifier.    Avoid  placing  this  system  close  to  other  heat  sources.  
Do  not  block  the  fan  or  underside  ventilation  holes  with  any  other  object.  
Make  certain  there  is  proper  ventilation  for  the  internal  amplifier  when  is 
use. 

 

  Do not drive the XMAX112 into excessive heavy distortion for an extended 

period of time to avoid premature speaker failure.  

 

  Failure to follow these instructions may void the warranty.  

 
 

 
 
 
 
 

Содержание Xmax 112

Страница 1: ...1 ...

Страница 2: ...gn objects or liquid into this unit This active speaker system has an internal amplifier and a heatsink located inside the back of the cabinet with an internal fan for cooling of the internal amplifier Care should be taken to avoid placing this active speaker in a location where the fan in blocked and does not allow proper cooling of the internal amplifier Avoid placing this system close to other ...

Страница 3: ...e to noise levels in excess of 90db may cause permanent hearing loss Below is a chart of the OSHA Occupational Safety Health Administration regulations for Occupational Noise Exposure Please note OSHA requires hearing protection for any work environment when the sound levels exceed those shown in Table G 16 when measured on the A scale of a standard sound level meter at slow response ...

Страница 4: ... temperature protection global limiting and transformer thermal protection The XMAX112 offers XLR balanced inputs and XLR balanced full range and High Pass outputs allowing connections for multiple speakers in a system A sensitivity adjustment knob allows you to adapt the XMAX112 speaker for a wide range of common signal levels The XMAX112 subwoofer cabinet is made of high quality 13 ply Baltic bi...

Страница 5: ...ll control the phase of the input signal feeding the internal amplifier but is configured to by pass the crossover for the XMAX112 subwoofer This will allow the use of an external crossover to configure the system This switch will not affect any of the balanced outputs 6 INPUT SENSITIVITY This control determines the overall input level of the signal to the power amp section of the subwoofer cabine...

Страница 6: ...he fuse cover module after it is pulled out NOTE A SMALL COMPARTMENT IS ALSO PROVIDED WITHIN THE FUSE COVER MODULE FOR STORING A SPARE FUSE 2 After replacing the fuse with another of identical specifications push the fuse cover module fully back into place ensuring that the fuse has snapped onto the fuse holder inside the power inlet module ...

Страница 7: ...7 CONNECTION DIAGRAM ...

Страница 8: ...igured to AES standards Audio Engineering Society These connections are connected in a loop through configuration from the inputs to the full range outputs and will accept a balanced line level input The standard phase configuration is that pin 2 is pin 3 is and pin 1 is shielded ground on the XLR ...

Страница 9: ...resetting Transformer has internal thermal fuse self resetting Transducer Low Frequency Transducer Diameter 1x12 Voice Coil Diameter 4 76 2mm Power Handling 500 watts RMS each D CAT Technology Power Amplifier Low Frequency Amplifier Power Output 1400 watts RMS THD 0 06 typical Line Input Power Voltage 120VAC 60 Hz Current 10 amps max 5 amps typical Power 1400 watts Physical Height 35 8 Front Width...

Страница 10: ...rnal amplifier is cooled with a small fan The XMAX112 is designed such that the temperature should never exceed a level where the global thermal protection becomes active If the internal fan fails or the ventilation system is blocked so that airflow is impeded the global thermal protect may activate which will attenuate the signal 40db when the temperature exceeds a preset point When the temperatu...

Страница 11: ...d ISP will not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial number has been tampered with in any way Should you have any questions for the repair department prior to returning the product please call 1 248 673 7790 NOTE This Product may be covered under one or more of the follow...

Отзывы: