iSP Technologies HDL3112 ACTIVE SERIES Скачать руководство пользователя страница 3

 

 

THIS UNIT CONTAINS POTENTIALLY LETHAL VOLTAGES.  TO PREVENT ELECTRIC SHOCK 

OR  HAZARD,  DO  NOT  REMOVE  THE  POWER  AMPLIFIER  MODULE,  INPUT  PANEL  OR  AC 
INPUT  PANEL.    NO  USER  SERVICEABLE  PARTS  INSIDE.    REFER  SERVICING  TO 

QUALIFIED ISP TECHNOLOGIES SERVICE PERSONNEL.  
 

 

 
The lightning bolt triangle is used to alert the user to the risk of electric shock.  

 

 

 
The exclamation point triangle is used to alert the user to important operating or 

maintenance instructions.  

 

Caution: Exposure to extremely high noise levels can 
cause permanent hearing loss.   

 

The HIGH DEFINITION

 

LINE 3112™ system is capable of producing in excess of 138db 

SPL  at  1  meter.    Continued  exposure  to  noise  levels  in  excess  of  90db  may  cause 

permanent  hearing  loss.    Below  is  a  chart  of  the  OSHA  (Occupational  Safety  &  Health 
Administration)  regulations  for  Occupational  Noise  Exposure.    Please  note:  OSHA 

requires  hearing  protection  for  any  work  environment  when  the  sound  levels  exceed 
those  shown  in  Table  G-16  when  measured  on  the  A  scale  of  a  standard  sound  level 

meter at slow response. 
 

 

 

 

                    

 
 
 

Содержание HDL3112 ACTIVE SERIES

Страница 1: ......

Страница 2: ...be obsolete Take care to avoid Care should be taken to avoid spilling any foreign objects or liquid into this unit Avoid expose of this equipment to dripping or splashing and ensure that no objects f...

Страница 3: ...ing or maintenance instructions Caution Exposure to extremely high noise levels can cause permanent hearing loss The HIGH DEFINITION LINE 3112 system is capable of producing in excess of 138db SPL at...

Страница 4: ...powered subwoofer or an external processor When using multiple boxes an external processor or equalizer must be used to provide an array EQ function which rolls off the lower frequencies and boosts th...

Страница 5: ...ove the placement and method of attachment to the structure prior to the installation of any overhead object The following performance standards should be provided to the professional engineer for des...

Страница 6: ...lude a ground float circuit to help avoid ground loops as a result of multiple cabinets connected in a system A 3 Band meter is provided to indicate when a signal is present in each of the 3 Bands and...

Страница 7: ...ssive current required from a single AC PowerCon inlet This panel also includes a panel mount AC protection fuse KNOW THE RULES OF SAFE RIGGING The system is designed to facilitate the suspension of t...

Страница 8: ...ifier is mounted on a heatsink that is internal to the cabinet Airflow is drawn in from the front and is forced through a port on the rear near the internal heatsink In addition the amplifiers are the...

Страница 9: ...112 15 10 to 15 degrees in 1 steps Frequency Resp 68 Hz 4 boxes to 17 KHz Construction Baltic Birch Plywood Dimensions 30 0 W x 14 1 H x 20 6 D Weight 85 lbs Amplifier 800 W RMS 3 channels high curren...

Страница 10: ...st be fully prepaid ISP will not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial n...

Отзывы: