Cat5 Connections 
 

The figure below shows the connections for each output A, B and C of each zone.  
Connections are done via standard Cat5 cables where pins 1 through 8 are connected 
common to the same pins 1 through 8 at each end.  As shown below two wires in the 

Cable are use for balanced audio and 6 wires are used for power with two providing 
ground and two for each of two 22VAC power signals fed down the cable.    

 

 

 
 

Remote Level Control Connections 
 

The figure below shows the connections used for the external Remote Zone Level 

Control.  The Master Control Module feeds 10VDC down a Cat5 cable are sets the zone 
level based on the DC Voltage that appears on pin 5 of the Cat5 cable.  The level 
adjustment is done with an internal Voltage Controlled Amplifier VCA which means that 
a simple DC voltage is used to set the remote level eliminating the need to feed low 

level audio down a long run of cable. 
 
 

Содержание HDDS

Страница 1: ......

Страница 2: ...If this warning is ignored a serious electrical shock or death may occur Do not attempt to service this unit No user serviceable parts inside Refer servicing to qualified ISP approved service personnel Never remove or defeat the ground connection on the power cord of this unit Care should be taken to avoid spilling any foreign objects or liquid into this unit Failure to follow these instructions m...

Страница 3: ...LING All warnings on this equipment and in the operation instructions should be adhered to and all operating instructions should be followed Do not use this equipment near water Care should be taken so that objects do not fall onto and liquids are not spilled into the unit through any openings The power cord should be unplugged from the outlet when the unit is left unused for an extended period of...

Страница 4: ...he HDDS technology The Master Control Module includes six zones that can be used independently or can be linked to work together allowing the system designer the flexibility to set up any system with the desired configuration The block diagram below shows the basic configuration of the Master Control Module ...

Страница 5: ... Master Level Control 10 Zone 5 Link Indicator when lit Zone 5 is linked to Zone 6 11 Zone 6 Mater Level Control 12 Zone 6 Link Indicator when lit allow zone 6 to link to another Master Control Module Zone 1 13 Power LED illuminates when the power is switched ON 14 Main Power Switch Rear Panel 1 Zone 6 connections 2 Zone 5 connections 3 Zone 4 connections 4 Link Out allows connection to an additio...

Страница 6: ...r light 2 When the rear panel link button is pushed in the front panel link light will illuminate indicating that the zone has been linked with the next zone in the Master Control Module When linked to the next zone the Master Level control will now control the level of both zones and the second zone level control will not have any effect on the level Zone Level Control The front panel Master Leve...

Страница 7: ...ws the installer to build stereo Zones if desired If stereo operation is desired you can for example connect left audio to Zone 1 and right audio to Zone 2 By linking Zone 1 and Zone 2 you can control both zones as a stereo pair and mentioned above NOTE Pushing the Link button on the rear of the Zone will illuminate the link LED on the front panel of the unit indicating that the zone is linked to ...

Страница 8: ...cable exceeding 150 feet the cable voltage drop will start to become a design factor The Cat5 cable will start to limit the total power capability once you exceed 75 feet of cable Where maximum power output is critical a more precise calculation can be done by following the speaker consumption guide Linking Zones The picture below shows Zone1 linked to Zone 2 Zone 3 linked to Zone 4 and Zone 5 lin...

Страница 9: ...nd and two for each of two 22VAC power signals fed down the cable Remote Level Control Connections The figure below shows the connections used for the external Remote Zone Level Control The Master Control Module feeds 10VDC down a Cat5 cable are sets the zone level based on the DC Voltage that appears on pin 5 of the Cat5 cable The level adjustment is done with an internal Voltage Controlled Ampli...

Страница 10: ......

Страница 11: ... 10 AMP MAXIMUM 120VAC AUDIO INPUT Balanced 20k input impedance Pin 1 GND Pin 2 Audio Pin 3 Audio OUTPUT PER ZONE 7 AMP CONTINUOUS 10 AMP PEAK MAX TOTAL OUTPUT CURRENT 33 AMPS LEVEL CONTROL INTERNAL VCA CONTROL REMOTE CONTROL LAW 10VDC OVDC 1V 10DB WEIGHT 18LBS ...

Страница 12: ...Drive Unit B Waterford MI 48329 Attn Repair Dept All shipping charges must be fully prepaid ISP will not be responsible for any damages incurred in shipping of any unit Any claim will need to be settled with the shipping company The warranty will be voided if the serial number has been tampered with in any way The warranty card must also be filled out and returned in order to activate the warranty...

Отзывы: