MEASUREMENT AND ASSEMBLY MANUAL 

 

Instruction validity: as of 1 August 2013 

6.2.4 INSTALLATION TO WALL USING ANGLE-SECTION BRACKETS, BOX 

– CT105 

Mark the position of angle-section brackets and holes to be drilled. For upper boxes having the width of max. 

1.5 m

, two 

brackets  are sufficient,  which must  be installed  in  a  distance  of  approximately  15

–20 cm from each end. For wider roller 

blinds, four brackets (two pairs) are necessary, one in a distance of 15

–20 cm from each end and the second in a distance 

of 50

–60 cm from the first one.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation holes must be placed at least 25 and 50 mm from the 

ceiling or any obstacle exceeding the box. Attach brackets using 

screws  and  components  suitable  for  the  type  of  structure  onto 

which  they  are  to  be  attached  (metallic  structure,  window  frame, 

wall,  other  material).  If  four  brackets  are  used,  ensure  that  the 

brackets  are  perfectly  aligned  ± 1 mm;  this  can  be  checked  by 

sliding  the  box  along  the  cut-outs  before  tightening  the 

attachment  screws.  Install  the  box  to  brackets  and  slide  it 

lengthwise until it is centred within the window wing. 

 

 

6.2.5 INSTALLATION OF GUIDE BARS 

Proper method of installation of guide bars to the box depends on the box model used, and whether the box  is attached to 

the ceiling, wall of directly to the guide bars. Only one type of guide bars is available 

– GC20. 

 

 

 

 

 

Содержание SCREEN ZIP

Страница 1: ...nt of an opening As a rule indicate the width of the opening which is to be shaded in the order form 2 x 40 mm Dimensions outside the stipulated limits must be consulted with the manufacturer H height...

Страница 2: ...s Power supply Electric power mains 230 V AC Frequency 50 60 Hz Voltage fluctuation tolerance 10 Interference level below 70 dB Operating conditions Ambient temperature 5 C through 50 C Relative humid...

Страница 3: ...tallation and wiring of the roller blind may only be carried out by qualified and authorised personnel Any intervention however small in the power supply requires a qualified electrician Faulty wiring...

Страница 4: ...ind function regularly Do not use the roller blind if maintenance is necessary 5 UNPACKING The SCREEN ZIP system is supplied partially assembled only the guide bars or cord accessories and ceiling bra...

Страница 5: ...ller blind can be installed using two different methods 1 direct installation to guide bars attached to a ceiling or wall 2 installation to a ceiling or frontal installation using special attachment b...

Страница 6: ...e upper box and the rear wall but the bracket is visible and not visually attractive installation of a bracket with wedges in the back is more aesthetically desirable but requires at least 5 cm of spa...

Страница 7: ...ed at least 25 and 50 mm from the ceiling or any obstacle exceeding the box Attach brackets using screws and components suitable for the type of structure onto which they are to be attached metallic s...

Страница 8: ...1 INSTALLATION OF GS40 GUIDE BAR For model ZIP only one type of guide bars is available GC20 The bar is supplied with pre drilled holes as per order from the front or from the side Placement of holes...

Страница 9: ...For exterior roller blinds installed with a sleeve passing through a wall and with a crank rod in the interior it is necessary to calculate the exact position of the hole for a 30 cm angular rod 15 A...

Страница 10: ...any persons or objects impede the movement of the roller blinds Do not connect two or more motors to the same control unit without using a group control unit Do not use light switches Do not connect...

Страница 11: ...operating the roller blind move your hands outside of the movement range to prevent compression Vibrations or excessive noise indicate damage or faulty installation of the roller blind 8 2 TESTING To...

Страница 12: ...eration can cause damage to the roller blind 9 1 SAFETY DEVICES The motor includes a disconnecting overheating protection Thermal disconnection is activated after approx 4 6 minutes of continuous oper...

Страница 13: ...sive tape directly onto the winding drum on the side opposite to where the fabric is moving Repeat applying further adhesive tape layers until the defect is completely removed Drum cover displacement...

Страница 14: ...ing operation Otherwise contact technical support Increased noise Motor failure Disconnect the motor test it and replace if necessary Motor blocks after a long period of service The motor is in the th...

Отзывы: