MEASUREMENT AND ASSEMBLY MANUAL
Instruction validity: as of 1 August 2013
7
6.2.4 INSTALLATION TO WALL USING ANGLE-SECTION BRACKETS, BOX
– CT105
Mark the position of angle-section brackets and holes to be drilled. For upper boxes having the width of max.
1.5 m
, two
brackets are sufficient, which must be installed in a distance of approximately 15
–20 cm from each end. For wider roller
blinds, four brackets (two pairs) are necessary, one in a distance of 15
–20 cm from each end and the second in a distance
of 50
–60 cm from the first one.
Installation holes must be placed at least 25 and 50 mm from the
ceiling or any obstacle exceeding the box. Attach brackets using
screws and components suitable for the type of structure onto
which they are to be attached (metallic structure, window frame,
wall, other material). If four brackets are used, ensure that the
brackets are perfectly aligned ± 1 mm; this can be checked by
sliding the box along the cut-outs before tightening the
attachment screws. Install the box to brackets and slide it
lengthwise until it is centred within the window wing.
6.2.5 INSTALLATION OF GUIDE BARS
Proper method of installation of guide bars to the box depends on the box model used, and whether the box is attached to
the ceiling, wall of directly to the guide bars. Only one type of guide bars is available
– GC20.