4.2 Door front panel

The front panels on the doors can be replaced or additional 
standard front panels in white, teak, mahogany or cherry can be 
mounted on top of the standard panel.
Use a screwdriver or a knife as a lever and pull off the lower door 
profi le. Unscrew the three screws holding the door lock.
Mount the extra panel on top of the existing one, fasten the door 
lock again and push in the lower door profi le.
See fi g. 5 and 6.
The INOX model has doors in stainless steel and it has not 
exchangeable door fronts.

3.1 Battery voltage sensor

To protect the batteries from becoming completely discharged, a 
battery voltage sensor switches off the compressor automatically 
at the following levels:

System Voltage

Cut-out

Cut-in

12 V

9.6 V (10.4)

10.9 V (11.7)

24 V

21.3 V

22.7 V

If the bridge between C and P is cut off, values within the () are 
valid.

4.3 Electrical connections/wiring for power supply

CR 195  is available in two versions, one is equipped with  
Danfoss 12-24 VDC electronic units and the other is equipped 
with AC-DC electronic units. It is important that following points 
are considered:

DC (12 or 24 volt)

The electronic unit must always be connected direct to the 
battery poles. Connect the positive/plus to + and the negative/
minus to - on the battery. Without proper positive/negative 
connections, the electronic unit will not work - it is protected 
against reverse battery connection. 
For protection of the installation, a fuse for each compressor 
must be mounted in the positive cable as close to the battery as 
possible. 
A 15A fuse for a 12V power supply and a 7.5A fuse for a 24 volt 
circuit are recommended. If a breaker box connection is used, it 
should be rated to a minimum of 30A.
Avoid extra junctions in the power supply system to prevent 
voltage drop from affecting the battery protection setting.
The light is connected to battery power on the electronic unit and 
the bulb must be selected 12 or 24 volt. Both types are included 
in the delivery.  
See wiring diagram fi g. 8 valid for both compressors.

AC (100-240 volt)

The live and neutral wires must be connected to the terminals 
marked 

L

 and 

N

 on the electronic unit. Nominal voltages from 

100 to 240 VAC 50/60 Hz. Upper safety cut out limit is 270 VAC 
and lower limit is 80 VAC.Earth connection is to be placed on the 
compressor foot near the electronic unit. There is a hole drilled 
in the foot for this purpose, use a 5/32” screw and nut and a ring 
cable shoe on the wire.
Connection of mains power plug must fulfi l valid electrical safety 
regulations and properly fused with 4A. Wire gauge, AWG18.

General AC/DC

Both AC an DC power supply can be connected to the electronic 
unit at the same time. AC will be preferred power supply source 
if that is the case. If the AC power supply is disconnected, a 
time delay of 1 minute  will be activated before the compressor 
continuous on DC power supply. If AC power supply is 
established there will be no delay in compressor operation, when 
power supply is shifting from DC to AC.The light power supply is 
connected to A and C. The output voltage on A and C is always 
regulated to 12 VDC. A 12 VDC bulb must be used for both 12 
and 24 VDC power supply systems.

See wiring diagram fi g. 9 valid for both compressors but the 
freezer does not have inner light.

3 Maintenance

The Isotherm refrigeration systems have a fully hermetic closed 
cooling system and do not require any maintenance or refi lling of 
refrigerant. 
The compressor is of domestic type and has a very high 
effi ciency and an outstanding life-time. The refrigerator/freezer 
shall be left in the boat during the winter. (If the temperature 
is below freezing point, the compressor may not start). The 
maintenance is reduced to periodically, not less than a year, 
cleaning of the condensers from dust. Use a soft brush and no 
sharp tools. Keep the cabinet inside clean. Use lukewarm water 
and a mild detergent for cleaning the inside. Put the doors, 
during not in operation periods, in their slightly open ventilation 
positions. Release the catch on the door for this purpose with a 
coin or a small screwdriver (fi g. 1 and 2) (not valid for Stailess 
steel version, “INOX”). Take out the bulb from the internal light to 
avoid power consumption or switch off a main switch if there is 
one installed connected to the refrigerator/freezer power supply. 
(Fig 3 and 4)

4 Installation instructions

Many boats have a space which is intended for a fridge. The 
Isotherm Cruise fridge has been designed to suit the general 
dimensions normally used for this purpose.
 The compressor should normally stand upright in the boat, but 
will operate at an angle of heel up to 30° and for short periods 
even more. The compressors on CR 195 are attached by its rear 
side.  
The refrigerator/freezer unit has a three side mounting fl ange to 
fasten the unit in place. It must also be standing on its feet.  
See installation dimensions on fi g. 10.
Avoid mounting close to a heat source, like gas ovens and 
heaters. Also avoid a position allowing direct sunshine on the 
refrigeration/freezer unit.
The mounting positon should be dry and protected from 
splashing water.

4.1 Ventilation

It is very important that the compressor/condenser units 
are well ventilated and that cold air can enter at the bottom, 
pass behind the fridge/freezer and warm air can leave at the 

top in the area where it is mounted. The natural fl ow of air 
from below and upwards behind the fridge can be increased 
by arranging ventilation openings at the rear.

Make sure there is a free area of 23 - 28 sq.in. below and behind 
the refrigerator/freezer to allow ventilation air to pass behind from 
below. See fi g 5.

3

Содержание CR 195

Страница 1: ...Stainless Steel INOX Installation and operating instructions Indel Marine USA Inc 3400 Gateway Drive Unit 107 Pompano Beach FL 33069 Tel 1 954 984 8448 1 800 422 9711 Fax 1 954 979 2533 E mail info i...

Страница 2: ...n 2 1 Temperature setting 2 2 User tips 2 3 Defrosting 3 Maintenance 3 1 Battery voltage sensor 4 Installation instructions 4 1 Ventilation 4 2 Door front 4 3 Electrical connections 4 4 Electrical wir...

Страница 3: ...n the air Repair of the refrigeration circuit must be done by a certified technician 2 Operation 2 1 Temperature setting The refrigerator and freezer units are fitted with manually operated thermostat...

Страница 4: ...source if that is the case If the AC power supply is disconnected a time delay of 1 minute will be activated before the compressor continuous on DC power supply If AC power supply is established ther...

Страница 5: ...nic unit Compressor makes only short start attempts Bad power supply too low voltage or a volt age drop at start attempts Discharged batteries Check cables and connections possible corrosion clean Cha...

Страница 6: ...Fig 1 Fig 2 Figures Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Ventilation principals Wiring diagram for CR 195 12 24 VDC 001084 Fig 8 Note No light in freezer compart ment 5...

Страница 7: ...7 Installation dimensions CR 195 CR 195 INOX Wiring diagram for CR 195 AC DC 000941 2 Fig 9 Fig 10 Note No light in freezer compart ment 6 2008 01 07 LLG CR195u...

Отзывы: