Fault finding chart

 

 

Fault  

 

 

 

Possible cause   

 

Action 

 
Box not cold. 

 

  

Compressor will not start. 

 

Check that power is present at  

 

 

 

 

 

 

 

 

 

 

electronic unit. 

 

 

 

 

 

 

 

 

 

 

Check fuse. 

 

 

 

 

 

 

 

 

 

 

Reversed polarity. 

 

 

 

 

 

 

 

 

 

 

Check all connections and cables. 

 

 

 

 

 

 

 

 

 

 

Bridge the thermostat. See wiring  

 

 

 

 

 

 

 

 

 

 

diagram. 

 

 

 

 

 

 

 

 

 

 

If compressor starts this indicates a  

 

 

 

 

 

 

 

 

 

 

faulty thermostat. 

 

 

 

 

 

 

 

 

 

 

If the compressor does not start this  

 

 

 

 

 

 

 

 

 

 

indicates a fault in the electronic unit  

Compressor starts but does 

 

 

 

 

 

or the compressor. 

Not cool the box.   

 

 

 

 

 

 

Contact an authorized service agent. 

 
 

Installation instructions 

 
Mount the box carefully and safe. It is vitally important that the compressor and the condenser 
are well ventilated and that cold air can enter and warm air can leave the space around the 
compressor unit. (Warm air is leaving upwards). 
Do not install the box close to warm areas as the stove, heater or the engine. 

 

Electrical connections 

 

When connecting the box electrically, it is important that following points are considered: 
 
*  Always use cables of sufficient area. The area in the following table should be regarded 
    as a minimum. 

 

 

Cable area mm²       Max cable length in metres, 12 V    Max cable length in metres, 24 V 

 

 

 

 

 

2.5 

 

 

 

 

2.5 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 

 

 

 

10 

 

 

 

 

10 

 

 

 

 

 

20 

 
*  Always connect the box directly to the battery or to the battery main switch on the plus 
    circuit. Do not connect it via the boats own control panel or other diversions as this can            
    cause a voltage drop in the power supply. Use the included fuse holder  with a 15A fuse.  
    The fuse shall be mounted on the plus cable. 

 

Содержание BI 40

Страница 1: ...uks installationsanvisning Build in boxes BI 40 Einbauboxen BI 40 Inbyggnadsboxar BI 40 Indel Webasto Marine S r l Zona Artigianale IT 61019 S Agata Feltria PU Italy Tel 39 0541 848 030 Fax 39 0541 848 563 E mail info indelwebastomarine com www indelwebastomarine com ...

Страница 2: ...ttles as cold as possible during the defrosting Do not use sharp metal objects to remove frost or ice Do not re start until the box is completely defrosted and dried BI 40 with ASU Control panel functions The refrigeration unit is switched off when the toggle switch is in the mid position NORMAL AUTO position The green light comes on indicating that power is being supplied and the refrigeration pr...

Страница 3: ...tic re start occurs when the engine is running and batteries are charged again Note After switching on up to 30 sec duration is required before the compressor starts When the engine is started a duration of to 10 minutes is required depending on the boats charging equipment and battery condition before the system reacts When the engine is stopped a duration of 5 minutes depending on battery condit...

Страница 4: ...ot start this indicates a fault in the electronic unit Compressor starts but does or the compressor Not cool the box Contact an authorized service agent Installation instructions Mount the box carefully and safe It is vitally important that the compressor and the condenser are well ventilated and that cold air can enter and warm air can leave the space around the compressor unit Warm air is leavin...

Страница 5: ...ger The battery charger must be connected to the battery Technical data Type designations Thermostat 3040EA2A00000 ASU 3040EE2A00000 Volume 40 litres Voltage 12 24 Volt Power consumption 2 5 5 A 12 volt when compressor is running Avarage consumption 0 5 0 8 A 12 volt at 6 C 43 F boxtemp and 22 C 72 F ambient temp Compressor Danfoss BD35F Refrigerant R134a Amount as per label on compressor Fuse 15A...

Страница 6: ...wenn er vollständig abgetaut und getrocknet ist Box mit ASU Bei mittlerer Schaltposition ist die Anlage ausgeschaltet Das Isotherm ASU Kühlsystem kann auf zwei Arten betrieben werden Schalter auf NORMAL AUTO Position die optimale Kühltemperatur wird automatisch eingehalten bei absolut niedrigstem Batterieverbrauch MAN TEMP Position die automatische Funktion ist teilweise blockiert die Kühltemperat...

Страница 7: ...ensor hat das System abgeschaltet Es erfolgt ein automatisches Neustarten wenn der Motor läuft um die Batterien wieder aufzuladen Hinweis Nach dem Einschalten dauert es ca 5 30 Sekunden bevor das System startet Wenn der Motor an ist dauert es bis 10 Minuten bevor das System reagiert abhängig von Ladeausrüstung und Batteriezustand Wird der Motor gestoppt dauert es bis 5 Minuten bevor das System Rea...

Страница 8: ...gut belüftet werden und daß kalte Luft am Boden einströmen und Warme oben entweichen kann Der Kompressor sollte senkrecht im Boot stehen er arbeitet aber bei einem Krängungswinkel bis zu 30 Grad über einen gewissen Zeitraum einwandfrei Elektrische Anschlüsse Wenn Sie die Kühl Gefrierbox anschließen müssen Sie folgendes beachten Verwenden Sie immer die richtige Kabelgröße korrekten Kabelquerschnitt...

Страница 9: ...Stromverbrauch 2 5 5A in Betrieb 12 V Mittlerer Stromverbrauch 0 5 0 8 A h 12 V bei Temperatur in der Box 6 C Umgebung 22 C Kompressor Danfoss BD35F Kältemittel R134a Füllmenge gemäß Schild am Kompressor Sicherung 15 A Auto Flachsicherung Abmessungen Länge 565 mm 400 mm ohne Kompressor Breite 400 mm Höhe 420 mm Gewicht 16 Kg Elektrische Anschlüße ...

Страница 10: ...mostaten tillåter reglering av temperaturen inom normal kylskåps kylbox temperatur Avfrostning Avfrostning skall ske då en tjock över 4 5mm frostbeläggning finns på förångaren Stäng av boxen på termostatvredet Förvara de matvaror och drycker som fanns i boxen så kallt som möjligt t ex frysväskor el dyl under tiden avfrostningen äger rum Använd inga vassa fö remål för att avlägsna isen Starta ej bo...

Страница 11: ...trömställaren läge MAN TEMP Blinkande gul Batterivakten har löst ut och stängt av aggregatet Starta motorn för laddning och kompressorn återstartar automatiskt Obs Då strömställaren slås till dröjer det ca 30 sek innan kompressorn startar Då båtmotorn startats dröjer det 10 min innan aggregatet reagerar beroende på båtens laddningsutrustning och batterikondition Då båtmotorn slås av dröjer det 5 m...

Страница 12: ...termostaten startar kompressorn då är termostaten felaktig Om åtgärderna i övrigt inte av hjälper felet kontakta auktori serad serviceverkstad Kontakta auktoriserad service verkstad Installationsanvisning Boxen skall sättas fast ordentligt i det utrymme som valts för montering Det är viktigt att god ventilation finns i utrymmet där boxen kompressorn är monterad Man skall därför se till att kall lu...

Страница 13: ...C omgivningstemperatur Kompressor Danfoss BD35F Köldmedium R134a Fyllnadsmängd enligt dekal på kompressorn Säkring 12V 15A alt 24V 7 5A Mått Längd 560 mm 400 mm utan kompressor Bredd 400 mm Höjd 420 mm Vikt 16 kg Elinkoppling ASU Automatic Speed Up 2008 02 26 LLG BI 40 C Thermoprodukter AB Dragonvägen 6 SE 392 39 Kalmar Sweden Tel 46 480 425 880 Fax 46 480 127 75 E mail info isotherm com www isoth...

Отзывы: