__________________________________________________________________________________
10 |
P a g e - S e i t e
Technical Data - Standard
__________________________________________________________________________________
Type:
IT-S20/S45 IT-G25
IT-ITH
IT-H
Area Classification:
Non-hazardous
Max. admiss. Temp.:
450°C (842°F) 450° (842°F)
450°C (842°F) 900°C ( 1652°F)
for cold lead and termination: 200°C (392°F) 300°C (572°F) 300°C (572°F) 300°C (572°F)
Min. Installation Temp.:
-40°C (-49°F)
-40°C (-49°F)
-20°C (-4°F)
-50°C (-58°F)
Min. Bending Radius:
15 mm
25 mm
15 mm
15 mm
Min.
Spacing:
5
mm
5
mm
5
mm
5
mm
Protection Class:
I
see insert*
see insert*
see insert*
IP-Rating:
IP20
Heating element:
var. alloys
var. alloys
var. alloys
NiCr
Electrical
Insulation:
Glass-fiber Glass-fiber Glass-fiber Silica-Glass-fiber
Outer Sheath:
Ni plated Cu
Glass-fiber
Glass-fiber
Silica-Glass-fiber
Structural carrier:
-/Glass-fiber
Glass-fiber
Glass-fiber
Silica-Glass-fiber
Nominal Length
(1)
:
refer to product spec. or data label
max. typical P value per m
(2)
: 220 W/m /
650 W/m
75-150 W/m
380 W/m
250
W/m
Nominal Power
(2)
:
refer to product spec. or data label
Operating Voltage:
230 Vac
230 Vac
240/110 Vac
230 Vac
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Nominal Operating Voltage:
refer to product spec. or data label
__________________________________________________________________________________
for other versions of the series types listed above - please inquire
Tolerances:
(1)
< 2.0 m ± (1% +50 mm)
> 2.0 m ± (2% +100 mm)
(2)
±10%
*) see technical data on additional paper