KEYPAD CONFIGURATION
R-1-MCT-WK Wall Mount Keypad reader (13.56 MHz, 125kHz, BLE, backlit)
If you are using your R-1-MCT-WK Pure IP™ reader with an ISONAS IP Bridge™ please execute the
following steps to establish 26 bit Wiegand communication:
1.
Power cycle the R-1 reader.
2.
Within 1 minute from powering on the unit, enter:
* 8 8 8 8 9 9 9 9
The LED will turn green and the keypad will beep three times.
3.
Within 5 seconds, enter the # followed by any three-digit facility code:
# ___
___
___
Note: Most sites will not have a site code already established. If there is no site code already
established, we recommend 0 0 1. Any three-digit code will work.
Example: #
0
0
1
The LED will turn green and the keypad will beep three times.
4.
If you are using ISONAS Pure Access Cloud or Pure Access Manager, you must specify the
configuration for “External Keypad Site Code” located on Settings -> Credential page.
Pure Access only allows one site code per installation.
In this mode, the reader sends the PIN (packaged as a 26-bit Wiegand output with the fixed
facility code). We recommend PIN numbers to be a four-digit number between 1 and
32767.
The PIN should always be entered starting with * and end with #.
Example: *
1
2
3
4
#
Isonas Inc 4750 Walnut St. Suite 110 Boulder CO 80301
800-581-0083