![iSolution Xperior 300SZ Spot Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/isolution/xperior-300sz-spot/xperior-300sz-spot_user-manual_2093474037.webp)
XP-300 SZ
36-
of the unit or the previous one.
4. Try to use another DMX controller.
5. Check to see if the DMX cables run near or run alongside to high voltage cables that
may cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
D. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal
temperature
may
be too high. Check if replacement of fan is needed on the
head.
E. If The pan belt is broken
1. Turn off the mains power.
2. Loosen the screws (A)
,
open the cover (B).
3. Loosen the screws (C).
4. Unplug all the connect wires over the belt.
5. Change a new belt (D), put the belt around the axis gear and
motor gear.
6. Plug all the connect wires back
upon the belt.
7. Tighten all the screws.
F. If The tilt belt is broken
1. Turn off the mains power.
2. Loosen all the screws (A) and open the right arm
cover (B).
3. Loosen the screws (C) that fix the bridge.
4. Change a new belt (D). Please adjust the tension
of the belt properly. Note: do not fix the belt too
tight as it is can easily rupture.
5. Reverse the procedures from step 3 to 2.
Содержание Xperior 300SZ Spot
Страница 1: ...XperiorTM 300SZ Spot User Guide Please read these instructions carefully before use...
Страница 14: ...XP 300 SZ 13...
Страница 31: ...XP 300 SZ 30...
Страница 32: ...XP 300 SZ 31 22 Channels mode 2...
Страница 33: ...XP 300 SZ 32...
Страница 34: ...XP 300 SZ 33 29 Channels mode...
Страница 35: ...XP 300 SZ 34...
Страница 40: ...Innovation Quality Performance...