7-
Stand by Blackout the unit
Function
Strobe
1.Gobo/Color sync.
strobe
2.Sync. strobe
3.Two-light strobe
X/Y moving show
mode selection
( Show 1 ~ Show 4 )
Please refer to Show
mode in 4.2 Main
Function.
Color/Gobo selection
1. Hold on for gobo
change.
2. Press shortly for
color change.
X/Y moving setting
1.Pan position
2.Tilt position
3.Dimmer
First set Master unit,
then set Slave units
’
position.
Mode
Sound 1
(LED off )
Sound 2
(LED normal blinking)
Slow/Sound 3
(LED on)
Position/ Latch
(LED fast blinking)
5.3.1 iSolution Operation
♦
Consistent DMX configuration enable iMove to be linked together with iRock and iShow
and controlled at the same time.
♦
DMX address can be set remotely by iLead controller ( please refer to the user manual
of iLead controller ). No need to calculate the DMX channels of each fixture in the chain.
♦
Automatic switching between DMX function and built-in stand alone programs.
5.3.2 DMX Controller
An universal DMX controller to control the units, you have to set DMX address from 1 to 512
channel so that the units can receive DMX signal.
Press the
MENU
button up to when the
is showing on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to change the DMX512 address.
Once the address has been selected, press and keep
ENTER
button pressed up to when the
display stops blinking or storing automatically 8 seconds later. To go back to the functions
without any change press the
MENU
button again. Please refer to the following diagram to
address your DMX512 channel for the first 4 units.
DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX
channels of each fixture in the chain.
3. Lamp
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful to
the eyes and skin. The high luminance of the arc can cause severe damage to the retina
if looks directly at the lamp.
Discharge lamp : HTI 150W
1. Always switch off the main supply and never handle the lamp or luminaries when is
hot.
2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp any longer than its specified life.
5. Make sure the lamp is located in the center of the reflector for the best spot. Adjust
lamp position by screws A, B and C.
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.