background image

7- 

Stand by  Blackout the unit 

Function 

Strobe 
1.Gobo/Color sync. 

strobe 

2.Sync. strobe 
3.Two-light strobe 

X/Y moving show 
mode selection 
( Show 1 ~ Show 4 ) 
Please refer to Show 
mode in 4.2   Main 
Function. 

Color/Gobo selection   
1. Hold on for gobo 

change. 

2. Press shortly for 

color change. 

X/Y moving setting 
1.Pan position 
2.Tilt position 
3.Dimmer   
First set Master unit, 
then set Slave units

 

position.   

Mode 

Sound 1 
(LED off ) 

Sound 2 
(LED normal blinking) 

Slow/Sound 3 
(LED on) 

Position/ Latch 
(LED fast blinking) 

 

 

5.3.1 iSolution Operation 

 

 

♦ 

Consistent DMX configuration enable iMove to be linked together with iRock and iShow 

and controlled at the same time.   

♦ 

DMX address can be set remotely by iLead controller ( please refer to the user manual 

of iLead controller ). No need to calculate the DMX channels of each fixture in the chain. 

♦ 

Automatic switching between DMX function and built-in stand alone programs.

 

 

  5.3.2 DMX Controller   

 

An universal DMX controller to control the units, you have to set DMX address from 1 to 512 

channel so that the units can receive DMX signal. 

 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when the 

display stops blinking or storing automatically 8 seconds later. To go back to the functions 

without any change press the

 MENU

 button again. Please refer to the following diagram to 

address your DMX512 channel for the first 4 units.   

 

DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX 

channels of each fixture in the chain. 

 

 

 

 

  3. Lamp   

 

 

 

 

Because of its high internal pressure, there might be a risk that the Discharge lamp 

would explode during operation. The lamp emits intense UV radiation which is harmful to 

the eyes and skin. The high luminance of the arc can cause severe damage to the retina 

if looks directly at the lamp. 

 

    Discharge lamp : HTI 150W   

1. Always switch off the main supply and never handle the lamp or luminaries when is 

hot. 

2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured 

alcohol and wipe it with a lint free cloth before installation. 

3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding. 

4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube 

rupture. The risk increases with age, temperature and improper handling of the lamp. Do 

not use the lamp any longer than its specified life.   

5. Make sure the lamp is located in the center of the reflector for the best spot. Adjust 

lamp position by screws A, B and C. 

 

 

 

 

 

 

In case of replacement of the lamp or maintenance, do not open the 

  fixture within 15 minutes until the unit cools down after switching off.

Содержание IH9000-1

Страница 1: ...ower AC 120V 60Hz or AC 230 240 250V 50 60Hz Fuse 20mm Glass T6 3A Fast Blow Lamp HTI 150W Dimension 373mm x 295mm x 451 mm Weight 13 kg Innovation Quality Performance IH9000 1 User Guide Professional...

Страница 2: ...damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean t...

Страница 3: ...in order to avoid electric shock The unit is for indoor use only Use only in a dry location The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be...

Страница 4: ...work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX...

Страница 5: ...ected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX512 sy...

Страница 6: ...cover If you wish to use other forms and patterns as the standard gobos or if the gobos are to be exchanged remove the fixation ring with an appropriate tool Remove the gobo and insert the new gobo Pr...

Страница 7: ...he display stops blinking or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX5...

Страница 8: ...r some noises for about 20 seconds After that the unit will be ready to receive DMX signal or run the built in programs 5 1 Master Slave Built In Preprogrammed Function You can select blackout mode in...

Страница 9: ...hen the is blinking on the display Pressing ENTER button and all channels of the unit will return to their standard position To go back to the functions press the MENU button again 4 2 Main Function T...

Страница 10: ...button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or split color mode Once the mode has been selected press...

Отзывы: